The outer wall must be fitted with one air inlet ventilation grille (fig. 2 3a,
page 8) and one outlet ventilation grille (fig. 2 3b, page 8) so that the heat
generated can be easily released to the outside:
Lower air inlet vent LS300 must be installed as flush as possible to the vehicle
floor.
Upper air outlet vent LS300 must be installed with the bottom of the vent no
lower than equal to the top of the refrigerator cabinet, the bottom of the top
vent can be higher than the cabinet.
Fit an air deflection plate (fig. 2 6, page 8) above the condenser so that the heat
does not accumulate in the vehicle.
Put insulation wool (fig. 2 1, page 8) on top and sides of the cabinet.
If the lower ventilation grille of the air inlet vent cannot be installed flush to the
floor, an additional inlet vent (fig. 2 4, page 8) must be provided in the floor for
releasing any possible gas leakage.
The distance between the refrigerator and the rear wall must be at least 10 mm.
The recommended maximum distance between the refrigerator and the rear wall
is 25 mm. A distance of more than 25 mm between the refrigerator and rear wall
leads to poor performance and increases the power consumption of the
refrigerator. Reduce the space behind the refrigerator to maximum 25 mm to
create adequate air inlet and outlet ventilation corridor (fig. 3). Use a ventilation
plate, for example, to do this.