Installation Guide
EN
Installing the refrigerator RUA6408X, RUA8408X
14
6.3 Making air inlet and outlet vents
I
➤ Make a cut out in the wall to fit an appropriate upper and lower vent system,
choose LS300 check the dimensions required for the vent. See chapter “Prepar-
ing the installation” on page 6.
➤ If the lower ventilation grille can not be installed flush to the door, make an air
inlet vent in the floor (fig. 2 4, page 8) behind the refrigerator near the gas
burner.
➤ Shield the end of the opening with a deflector to prevent sludge or dirt from
getting inside while driving (fig. 9).
If you have to use a roof vent instead of an upper wall vent:
➤ Cut out a section in the roof. Refer to the roof vent instruction manual for the
required dimensions. When doing so, observe the information, see chapter “Pre-
paring the installation” on page 6.
NOTE
At high ambient temperatures, the refrigerator can only provide its max-
imum cooling capacity if the optimum ventilation has been provided.
≥ 40 mm
9
RUA8408X-I-AU.book Seite 14 Donnerstag, 12. April 2018 12:16 12