RUA6408X, RUA8408X Installing the refrigerator
11
If a roof air conditioner is installed, the distance between the roof vent
(fig. 5 1) and the air outlet of the roof air conditioner (fig. 5 2) must be at
least 300 mm.
The refrigerator must not be installed at the side of the air inlet and outlet vents as
this leads to poor performance and increases the power consumption of the
refrigerator.
The air inlet and outlet vents must not be covered by vehicle parts (such as an
open door or by installing accessories such as bicycle racks) while operating.
A separate flue duct must be installed under the air outlet vent, see chapter
“Installing the flue duct” on page 19.
Install the refrigerator so that it is protected from excessive heat, as this leads to
poor performance and increases the power consumption of the refrigerator.
The electrical installation must comply with national and local regulations.
The gas installation must comply with national and local regulations.
AS 5601.2 – Gas Installations
NZ 5601 – Gas Appliance Safety
The refrigerator must be installed in a draught-proof location, see chapter “Install-
ing the refrigerator in a sealed location separate to the living space” on page 12.