RMDX21, RMDX25 Troubleshooting
35
➤ Attach the burner cover.
✓ The burner cover is fixed in place when it audibly clicks into place.
➤ Screw the burner cover in place.
➤ Insert the condensation container.
➤ Attach the ventilation grille.
10 Troubleshooting
Problem Possible cause Suggested remedy
With AC operation:
The refrigerator does
not work.
The fuse in the AC mains
is defective.
Replace the fuse.
The vehicle is not con-
nected to the AC mains.
Connect the vehicle to the
AC mains.
The AC heating element is
defective.
Contact the authorised
customer service.
With DC operation:
The refrigerator does
not work.
The fuse in the DC supply
is defective.
Replace the fuse.
The vehicle fuse has
blown.
Replace the vehicle fuse in the
DC socket (usually 15 A)
(Please refer to the operating
manual of your vehicle).
The vehicle battery is
discharged.
Test th e b at te ry and c h arge it .
The ignition is not turned
on.
Switch on the ignition.
The DC heating element is
defective.
Contact the authorised
customer service.
With gas operation:
The refrigerator does
not work.
The gas cylinder is empty. Replace the gas cylinder.
The gas valve is closed. Twist the valve open.
Air is in the supply line. Switch the refrigerator off
and on again. Repeat the
procedure three or four times
if necessary.