Product Manual
EN
Maintenance RMDX21, RMDX25
34
9Maintenance
!
I
➤ Have the gas system and connected flues inspected before initial
operation and then periodically as required by an authorised professional
to ensure they comply with national safety requirements.
➤ The gas burner can be cleaned of impurities whenever necessary. Vermin
infestation is possible after extended periods without using gas operation.
Yearly inspection of the burner is suggested.
➤ Keep a record of any maintenance performed in the vehicle.
9.1 Cleaning the gas burner
!
➤ Remove the ventilation grille (fig. i, page 12).
➤ Take out the condensation container (fig. j, page 12).
➤ Loosen the screw on the gas burner cover (fig. j, page 12).
➤ Press the catch below the burner cover inwards, and pull off the burner
cover (fig. j, page 12).
➤ Clean the burner pipe of coarse impurities using a suitable cleaning brush
with soft bristles (fig. k, page 12).
➤ Blow out the burner pipe with compressed air through the slots in the
burner pipe (fig. l, page 12).
WARNING!
Working on gas and electrical installations may only be performed
by qualified technicians.
NOTE
Have the refrigerator checked if the vehicle has not been used for
a long time. To do this, contact the customer service.
WARNING!
Disconnect the AC power supply.
Close the gas valve to the refrigerator before cleaning the gas
burner.
Allow the burner to cool down before cleaning it.
Do not modify the gas equipment. The gas burner can be
cleaned without removing the gas equipment.