Installation Guide
13
The exhaust gas duct system must be made in
such a manner as to achieve a complete
extraction of combustion products to the out-
side of living space. The flue gas is vented
directly through the upper grille. Do not use
any kind of aluminium flue pipe to lead the flue
gas out.
The T-piece (Fig. 20) must be aligned with the
exterior wall.
An installation other than described will
reduce the cooling capacity and jeopardi-
se the manufacturer's warranty/product
liability.
CAUTION!
4.4 Exhaust duct system
Fig. 20
45°
Fig. 18
Seal the installation
bays and screw them
to the vehicle roof.
1
Fig. 19
Place the hood in
postion and screw it
to the installation
bays.
2
Fig. 17
Installation
Open cross-section of roof exhaust
minimum 640 cm²
Please be aware that the L 500 vent grille is
equipped with locking screws instead of sli-
ders.
4.3.2 Installing roof exhaust vent