4.3 Installing the ventilation system
Fig. 11
Minimum height of ventilation
LS300
L500
LS300
L500
H
Fig. 12
Cut two rectangles in the
exterior wall of the vehi-
cle.
1
Fig. 12
Seal the mounting frame
making it waterproof
(
does not apply for
mounting frames with
integral seal)
and screw
into position.
2
Fig. 14
Insert ventilation grille.
3
Fig. 15
Install locking slider.
4
Fig. 16
Lock ventilation grille.
5
4.3.1 Installation LS300 or L500 (NZ)
b
a
14 x
Installation of lower and upper ventilation
grilles LS300.
Correct mounting of the lower ventilation gril-
le facilitates access to the connections and
functional parts during maintenance.
An installation other than described will
reduce the cooling capacity and jeopardi-
se the manufacturer's warranty/product
liability.
CAUTION!
To install the ventilation grilles cut two rectan-
gles to suit in the outer wall of the vehicle (for
position of the cuts, see Fig. 13).
ventilation aperture
Ø min 40 mm
The bottom of the upper ventilation grille must
be equal to or above the height of the refrige-
rator.
Installation