CARAVAN MANUAL RM 4290 RM 4291 Deutsch English Français Italiano Español Seite page page pagina pagina Typ C40 / 110 821 2685-02 1 7 13 19 25 Svenska Dansk Norsk Nederlands Suomi Português sida side side pag. sivu cara 31 37 43 49 55 61 T.B.
OPERATING AND INSTALLATION INSTRUCTIONS FOR ELECTROLUX REFRIGERATORS INTRODUCTION CONTENTS We are pleased that you have chosen this refrigerator and hope you will derive much satisfaction from using it, but first a few well-meant words of advice: OPERATING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . 8 CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 It is important to read through these instructions carefully before using the refrigerator.
OPERATING INSTRUCTIONS 8. Keep the (D) button pressed for a further 10 to 15 seconds to active the flame failure device, then release it. CONTROLS If you have Model RM 4290 proceed as follows: 3. Turn on the gas supply by pressing the (D) knob and turning it to the position The refrigerator can be run on either 230 V, 12 V or LP gas. Changing between these modes of operation is carried out by means of the controls of the control panel shown in fig 3. 4.
TRAVEL CATCH CLEANING THE REFRIGERATOR Make sure that the travel catch is engaged when the caravan is on the move, (fig 1). Clean the inside of the refrigerator regularly to keep it fresh and hygienic. The travel catch at the top of the door can be set in two different positions. In one position the door is held tightly shut. In the other position the door is secured ajar so that the refrigerator can be aired when not in use.
2. The evaporator is frosted up. TECHNICAL DATA 3. The temperature control setting is incorrect. Overall dimensions, refrigerator Height . . . . . . . . . . . . . . . . . . . . . . . .815 Width . . . . . . . . . . . . . . . . . . . . . . . .525 Depth (incl. cooling unit) without door. . . . . . . . . . . . .500 with door. . . . . . . . . . . . . . . .539 4. The gas pressure is incorrect - check the pressure regulator at the gas container. 5. The ambient temperature is too high. 6.
panel by sliding it downwards. condenser (C) of the refrigeration unit, at least as shown in fig. 6b but preferably as shown in fig. 6a. ● Fit new panel in place and slide it up as far as possible. ● Fit the trim moulding back in place. Ventilation grilles Fig. 2 The openings in the caravan wall must be fitted with the Electrolux ventilation systems. BUILDING-IN The refrigerator is intended for installation in a caravan or motorhome, and the description relates to this application.
The supply pipe should preferably be of copper. If any other material is used, it must be of a type approved for use with continuously operating bottled- gas appliances, and have threaded compression connections throughout. PUSH-ON CONNECTIONS MUST NOT BE USED (We do not approve the use of "rubber" type flexible tubing for connecting permanently operating appliances of this type in the United Kingdom). All connectors etc.