Operation Manual
3
INSTALLATION INSTRUCTIONS
VENTILATION REQUIREMENTS
The installation shall be made in such a manner as to separate
the combustion system from the living space of the mobile
home or recreational vehicle. Proper installation requires one
lower fresh air intake and one upper exhaust vent.
-
-
tor compartment must be provided for ventilation of heavier-
than-air fuel gases. The lower vent of the recommended kits
-
tion and ventilating air must not be obstructed.
ready serviceability of the burner
refrigerator. This should be cen
erator.
GENERAL INFORMATION
The installation, servicing and gas installation must be per-
must be installed in accordance with the manufacturers in-
building codes, electrical wiring regulations, AS5601.2 “Gas
Installations” and any other statutory regulations.
PACKAGING
The packaging of this appliance is design to withstand the
transportation from the factory to the point where it will be
installed in the recreational vehicle.
Before starting to install the appliance, please, make sure all
parts of the packaging have been removed, so there will not
be anything left that may come into contact with heat parts of
the appliance or obstruct the combustion exhaust gases or the
air movement around the cooling unit.
G
KK
L
M
adequate access opening for
control manifold of the
tred on the back of the refrig
and
-
CLEARANCES
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL
Top
G
0 mm
Side
K
Bottom
L
Rear
M
1
0 mm
0 mm
0 mm
25 mm
Fig 1
Ventilation components are:
1 X TP (Includes 1 x Tee piece & 1 x extension)
extra extensions may be requ ired depen ding on the
height of refrigerator and vent height. Part number
TPX
AS1625 vent kit
TP Kit
TPX
Extension
(Recommended)
(Recommended)
If the lower grille is not at floor level where leaking gas can
escape,a 40 mm hole to the outside should be made in the
floor of the recess to drain any unburned gas to the outside.Fit
the hole with wire mesh and an angled plate to protect it from
stones,mud etc.
MINIMUM VENTILATION REQUIREMENTS
SUGGESTED VENTILATION SYSTEM
(NOT INCLUDED)
Optional ventilation hole
minimum 40 mm dia
1 X AS1625 vent kit (Top &bottom vents with frames)