User manual

12
Check to make sure the slots are centred under the
ue tube and that the thermocouple is positioned
properly (tip of thermocouple extends over two
slots of burner). Note that the colour of the ame
should be clear blue over the slots of the burner.
Be sure to reconnect the wire to high voltage
electrode. Check the electrode for proper location
and gap.
Open the gas valve by turning knob A to (GAS).
Check all ttings for leaks with soapy water.
Connect 230-240 volt power cord to the outlet and
reconnect the 12 V DC power.
Check LP gas safety shutoff.
14.
15.
16.
17.
18.
19.
Clear blue colour
of flame
MAINTENANCE & SERVICE
Electrode
Burner tube
1/8” to 3/16”
(3-5 mm)
TROUBLESHOOTING
Refrigerator does not cool properly
Burner jet clogged.
Check level of refrigerator.
Venting problem.
Heavy frost buildup on evaporator ns.
Flue bafe not inserted properly in ue tube.
Improperly set thermostat.
Burner dirty.
LP gas pressure low at burner.
(Set main regulator so pressure does not drop below
2,7 kPa at pressure tap.)
Burner not located properly under ue tube.
Burner damaged.
Odour from fumes
Dislocated burner
Damaged burner
Dirty ue tube