Service manual
This program will address the most common system problems associated with the 
RM2150/2190/2201
 Manual
Refrigerators supplied by The 
Dometic
 Corporation. Our intent is to provide you with a guideline of checks to make,
should you encounter one of the following symptoms.
REFER
SYMPTOM 
CAUSE
SECTION 
STEP
1. No AC operation, (RM2201) 
Operation 
1.3
AC Volts 
2
Heating Element 
3
Thermostat 
5.5
Switch 
5.1 
B
Wiring 8.2
2. 
No gas operation 
-
 no spark. 
Operation 1.1,1.2,1.3
Piezo Igniter 5.2
Electrode 
5.3
Switch 
5.1 
A or B
Wiring 
8.2
3. 
No gas operation 
-
 sparks but no flame. Operation 
1.1,1.2,1.3
LP gas 
6
Filter 
7.2
Orifice 7.10
Burner 
7.6
Shut-off Valve 
7.1
Safety Valve 7.4
Thermocouple 
7.5
4. 
No cooling on any mode. 
Operation 
1 
.1
,1.2,1.3
Ventilation 
9.2
Level 
9.1
Ambient Temperature 
9.5
Cooling Unit 
9.6
5. 
No cooling on gas 
-
 cools properly on other 
LP Gas 
6
mode(s). 
Thermostat 
7.3
Filter 
7.2
Orifice 7.10
Burner 
7.6
Flue Baffle 
7.7
Flue Tube 
7.9
6. 
No cooling on AC 
-
 cools properly on other 
AC Volts 
2
mode(s). (RM2201) 
Heating Element 
3
Thermostat 
5.5
Switch 
5.1 
A or B
Wiring 
8.2
7. 
Insufficient cooling on all modes. 
Operation 
1.1,1.2,1.3
Level 
9.1
Ventilation 
9.2
Ambient Temperature 
9.5
Air Leaks 
9.3
Thermostat 
7.3
Thermostat (RM2201) 
5.5
Cooling Unit 
9.6