Service manual

Bulletin
#R58/7A
continued
Lastly, the moisture shield kit has been enclosed and can be
installed to prevent corrosion
damage caused by water or car wash solution being sprayed into the back of the refrigerator
through the vent louvers.
The circuit board compartment should be sealed in the following
manner:
a.
Install the shield under the bottom mounting bracket of the cooling unit. See the drawing
below by model number. Seal the top edge with the foil tape supplied.
b.
Seal around the conduit,
where it goes into the circuit board compartment, with putty
tape supplied or a silicon sealant can be used.
FOIL TAPE
ALONG TOP
Model 763
\
Model 663
NOTE: The earlv series
only
which has the
rectangular boiler
enclosure, requires
that the shield be bent across the middle
slightly (I),
with a little more angle on
the upper tab (2).
Models with the interior light conduit
(3) coming out of the top of the circuit
board housing may require a trimmed
slot and putty tape around the conduit
and slot.
Caution should be used when washing the vehicle
and avoid spraying water onto the refrigerator.
A-11-8