Now hook up a manometer to the test fitting
and leave it in place until all checks have been
made for gas operation. Turn the shut-off
valve and refrigerator on and check for a gas
pressure reading. A correct reading would be
eleven (11) inches water column pressure. If
needed, adjust the main gas regulator at the
LP gas tanks.
(137)
If you do not obtain any pressure, you must
check the electric solenoid. To diagnose the
electric solenoid windings, do the ohms
resistance check that was discussed earlier in
this program. (See page A-6-36, paragraph
106)
(138)
Another check is to disconnect the electric
solenoid wires. Supply DC voltage to the
BOTTOM terminal of the electric solenoid by
means of a temnorarv jumper wire from the
positive terminal on the terminal block.
A-6-45