Service manual

(84)
If
the 12 volt circuit is wired as shown on page
A-6-31, the battery will not be able to
properly filter the converter voltage. This
could cause erratic operation or premature
printed circuit board failure. Remember, the
positive and negative DC power leads to the
refrigerator must come directly from the
battery.
LP GAS SUPPLY
-
A.E.S. refrigerators use
liquid petroleum gas (propane) that is adjusted
to provide a pressure of 11 inches water
column pressure at the refrigerator test plug;
with at least
l/2
of the coach’s LP gas load in
operation.
(86)
A periodic leak check of all the LP gas
connections
is
recommended
using a
noncorrosive
type
of bubble solution.
WARNING: DO NOT use a flame to check for
leaks.
(87)
If, during the lighting sequence, attempts to
start the LP gas flame are not successful, make
sure the LP tank is not empty. Also, insure
that all of the manual shut-off valves are
turned on and are in the open position.
(see page A-6-31)
A-6-30