Service manual

(33)
As we stated earlier, in normal operation the
L.E.D. lamp will illuminate green.
(34)
On the LP gas mode, if a proper gas flame is
not
established within approximately 3
minutes, the lighting sequence will shut off
and the L.E.D. will begin flashing red to warn
the customer that the refrigerator has failed to
light on LP gas. This does not always indicate
that the refrigerator is broken. It is simply a
warning device to let the customer know that
the refrigerator did not light due to a lack of
LP gas, that the burner is dirty or there is air
in the LP supply lines.
(35)
To reset the lighting sequence; turn the main
switch to the off position, wait approximately
5 seconds, then turn it back on. This will reset
the controls to provide another approximate 3
minute lighting period as well as to reset the
L.E.D. lamp to green. If, repeated attempts to
light the system fail, troubleshooting the LP
gas system is in order, which we will discuss in
the troubleshooting segment of the program.
A-6- 10