miniBar RH 456LDE RH 456LD Type: MB20-60 Free-standing and Built-in versions Operating Instructions 207.5907.
Please read these operating instructions carefully before putting the refrigeration unit into operation. If you later sell or dispose of it, please ensure that the new owner receives these operating instructions. Please follow the installation details below carefully. Guarantee is valid for products installed as described only. (See chapter 4.1) Thank you for choosing our appliance. We are sure it will provide you with trouble-free use.
CONTENTS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Unpacking View of the appliance Cleaning Positioning the appliance 4.1. Installation instruction 4.1.1. Built-in version 4.1.2. Free-standing version Using the appliance 5.1. Initial operation 5.2. Temperature regulation 5.3. Cooling unit control (CUC) Ice cubes Useful suggestions Defrosting, cleaning and maintenance 8.1. Light 8.1.1. Interior light of the cooled Compartment 8.1.2. Interior Light of the uncooled Compartment 8.2.
1. Unpacking After removal from the cardboard packaging, make sure the appliance is not damaged. If you find damage to the appliance resulting from transport, report it immediately to the transportation firm. 2. View of the appliance RH456LDE RH456LD Built-in version Free-standing version Figure 1. 1. 2. 3. 4. 5. Door Door lock (if available) Ice tray (if available) LED Lamp Illumination of the uncooled Compartment 6. Storage compartment (uncooled) 7. Evaporator cover 8.
3. Cleaning Clean the refrigerator thoroughly at intervals, as necessary. Remove the shelves; these, parts, as well as the cabinet interior and the door should be washed with a warm solution of sodium bi-carbonate. Finally wipe over with a cloth rinsed in warm water only, and dry with a clean cloth. Do not wash any plastic parts in water that is more than hand warm, and do not expose them to dry heat. The outside of the cabinet should be wiped down regularly with a clean, damp cloth.
D Air out C min. 60 mm Air out Ventilation grille miniBar miniCool miniBar miniCool Air in Air in Figure 4. During installation, please ensure the mains plug is accessible at all times. 4.1.2. Free-standing version This version is supposed to be used free-standing. The cowl of the appliance is supposed to protect the user from the hot parts of the cooling unit of the appliance.
8. Defrosting, cleaning and maintenance This miniBar is fitted with an automatic defrost system Automatic defrost function The first defrosting phase commences 39 hours after the start and lasts for two hours. After this, the device operates for 22 hours at a time, followed by a defrosting period of 2 hours. The frost will melt and the defrost water will run through the drain tube from the drip channel into an evaporating vessel located at the bottom rear of the refrigerator.
9. Replacing the decorativ door panel (Fig. 10-12.) Disconnect the mains, and lay the appliance on its back. Remove the four screws (1) from the lower hinge of the door. Remove the door downwards from the upper hinge bolt.(2-3) Remove screws (4) and pull off the frame edge (5). Slide the decorative panel (6) out of the door frame and insert the new panel (7), so that the upper edge of the panel runs exactly parallel to the upper edge of the frame.
11. Putting into operation Technical data: Model Type Gross volume Cooled volume Uncooled volume Mains operation Input Energy consumption Refrigerant RH 456LD RH 456LDE (Built-in) MB20-60 56 litres 40 litres 16 litres 220-240V (AC) 65W 0.9 kWh/24h 159g H2O+86g NH3 11.1. Connecting to electrical mains The appliance may only be operated from nominal voltage mains as shown on the data plate. The appliance mains plug may be connected to a mains socket earthed in accordance with regulations.
Printed by Océ Hungária Kft. 2008. 06. 20.