R miniBar RH 439D RH 449D Type: MB20-60 Free-standing and Built-in versions Version pose libre et version encastrable. Operating Instructions Mode d'emploi 2002714 207.5396.
GB Please read these operating instructions carefully before putting the refrigeration unit into operation. If you later sell or dispose of it, please ensure that the new owner receives these operating instructions. Please follow the installation details below carefully. Guarantee is valid for products installed as described only. (See chapter 4.1.) Thank you for choosing our appliance. We are sure it will provide you with trouble-free use.
GB CONTENTS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Unpacking View of the appliance Cleaning Positioning the appliance 4.1. Installation instruction 4.1.1. Built-in version 4.1.2. Free-standing version Using the appliance 5.1. Initial operation 5.2. Temperature regulation 5.3. Cooling unit control (CUC) Useful suggestions Defrosting, cleaning and maintenance 7.1.
GB 1. Unpacking After removal from the cardboard packaging, make sure the appliance is not damaged. If you find damage to the appliance resulting from transport, report it immediately to the transportation firm. 2. View of the appliance Built-in version Free-standing version Figure 1. 1. 2. 3. 4. 5. Door Door lock (if available) Evaporator cover Evaporator sensor (behind evaporator) Evaporator 6. 7. 8. 9. 10.
GB 3. Cleaning Clean the refrigerator thoroughly at intervals, as necessary. Remove the shelves; these, parts, as well as the cabinet interior and the door should be washed with a warm solution of sodium bi-carbonate. Finally wipe over with a cloth rinsed in warm water only, and dry with a clean cloth. Do not wash any plastic parts in water that is more than hand warm, and do not expose them to dry heat. The outside of the cabinet should be wiped down regularly with a clean, damp cloth.
GB D C 6. Useful suggestion Air out Do not overfill the appliance. If possible, always store pre-cooled food and/or drinks. It is advisable to leave some space between the products in the cabinet to ensure efficient and even cooling. If the shelves are packed too tightly there may be unacceptable temperature variations. Ventilation grille Air out min. 60 mm miniBar miniCool miniCool miniBar Air in Air in Figure 4. During installation, please ensure the mains plug is accessible at all times.
GB 7 Check that the door closes easily and is sealed properly. 5 6 9 8 1 3 4 2 Figure 6. Take down the two foot-extension (1) pieces by removing the two screws (2) Remove the four screws (4) and take out the two fixing feet (3) Remove the four screws (7) the upper hing (5) and the cover cap (6) Remove the door (8), together with the upper hinge (5), from the housing Insert the upper hinge (attached the miniBar) and the covering plate in the slot on the opposite side and secure with four screws (7).
GB 11. Putting into operation Technical data: Model Type Gross volume Mains operation Input Energy consumption Climate class Refrigerant RH 439D MB20-60 24,5 litres 120 V (AC) 65W 0.7 kWh/24h N 147g H2O+98g NH3 RH 449D MB20-60 30 litres 120 V (AC) 65W 0.8 kWh/24h N 13. Recycling After unpacking the appliance, the packing materials should be delivered to a local collection site.
Printed by Océ Hungária Kft. Rev.: 2006. 03. 10.