Type: A30-100C Model: RF60 Operating instructions 207.5912.
E A B C D Figure 1 A. Energy selector switch B. Flame indicator (galvanometer) C. Thermostat (Gas/electric) D. Manual ignition button E. Door lock Note: The refrigerator is equipped to operate mains power, DC or liquid gas. The desired power option is selected by means of energy selector switch (A). Energy selector switch (A) has four settings: AC mains power, DC (12V), Gas (liquid gas), O (Off).
Dear customer, please read the instruction book and all additional information before using the appliance. It is most important that they should be retained with the appliance for future reference! 1. Warnings and directions These warnings are provided in the interest of safety.
Operation using liquid gas is permitted only in well ventilated rooms which have a capacity (length x width x height) of at least 20m3 and have a window (which can be opened) or a door to the outside - or out of doors. Outdoor use includes tents (awnings) which are well ventilated throughout unit operation and flat garden terraces. There are no restrictions on electrical operation. Site of operation must be protected from rain and other water sources. 3.
removed using a small screwdriver to lever it out. The old fuse should be replaced by a 3 amp ASTA approved BS 1362 fuse and the fuse cover/carrier must be refitted before the plug is used again. If the fuse cover/carrier is lost, a replacement can be obtained from the service shops. The fuse cover/carrier must be of the same colour as that of the coloured insert in the base of the plug. In no circumstances must the plug be used without a correct fuse cover/carrier fitted.
To turn on (Fig. 3) - Energy selector switch (A) should be in position “AC”. - Turn electric/gas thermostat knob (C) clockwise to position MAX. Only after approximately 1 hour will the unit become noticably cool (frost on evaporator). - The temperature can be regulated using the electric/gas thermostat knob: '0'=off, the symbol shows increasing degrees of coolness. - After sufficient cooling (approximately 5 hours), the thermostat position can be set to a lower temperature. (Middle position).
It is necessary to consider the polarity when connecting the unit. Check that the battery voltage and line voltage data correspond to the type-plate on the inside of the unit. If no batteries are used independently of the vehicle, the mobile cooler should not be operational when the vehicle is in motion, since the battery can discharge to the extent that the vehicle engine cannot restart when the vehicle is at a standstill. Recommendation: before journey, pre-cool the unit using AC operation.
9. Connection of gas supply (The following instructions refer in the main to coolers manufactured for the United Kingdom. For other countries please refer to your supplier). Always connect in the following sequence: GAS BOTTLE → PRESSURE-REGULATOR → APPLIANCE. To connect the appliance to the pressure-regulator an APPROVED FLEXIBLE GAS TUBE must be used. This must not be longer than 1,5 m - and should have an inside dimension of 8 mm.
max position D A C Figure 5 middle position 3. Turn thermostat knob (C) to the MAX position, press and hold down. 4. After approximately 10 seconds press knob (D) several times. (This could take longer than 10 seconds if the unit has been out of operation for a prolonged period or after replacing the gas cylinder. Cause: air in the pipes.) 5. After ignition, hold down knob (C) for a further 20-30 seconds before releasing. The flame can be controlled by flame indicator (B).
cooler as soon as an approximately 5mm thick layer of ice has formed. This is done by turning off the unit and removing any food or drink therin. Never use heated appliances, heaters, etc. to speed up the defrosting process! If necessary, a cloth dipped in warm water can be placed on the unit to help the defrosting process. After defrosting, clean up the defrosted water with a clean cloth and clean the cooler containers as described in chapter 4.
16. Reversing the door hang The direction the door opens can be transfered from one side to the other by carrying out the following steps: 1. Disconnect at the mains 2. Remove the door lock (E). 3. Remove the hinge bolt from the upper door hinge by screwing it off, using a screwdriver. 4. Detach the door. 5. Lay the refrigerator down carefully on its back. 6. Remove the hinge bolt from the lower door hinge by screwing it off, using a wrench nr. 11. 7.
The warranty does not apply if the installing and operating instructions are not adhered to. When contacting Dometic Service Network, please state the model, product number and serial number. You will find this information on the data plate inside of the refrigerator.
21. Technical Data Gas operation butane (propane): Rated thermal loading: 151 W (133 W) Min. thermal loading: 143 W (85 W) Connected load, gas: 11 g/h (9,5 g/h) Connection pressure: 28-30/37 mbar Categorie: I3+ Climat class: 'N' Electric operation: 220V-240V (mains) 50 Hz: 110W 12V (car battery): 110W Capacity: 61 Ltr. Refrigerant: 357g. H2O + 168g NH3 The refrigeration cycle has been checked for leaks. 22. Environmental protection information The appliance does not contain any CFCs/HCFCs.
Seal Fig 6 Seals Fig 7 14
Printed by Océ Hungária Kft. 2008. 12. 15.