RC 1600 EGP Type: JCB - 1 Operating instructions 207.5013.
Dear customer, please read the instruction book and all additional information before using the appliance. It is most important that they should be retained with the appliance for future reference! 1. Warnings and directions These warnings are provided in the interest of safety. You must read them carefully before installing or using the appliance! This product is designed to be operated by adults. Children should not be allowed to tamper with the controls or play with the product.
There are no restrictions on electrical operation. Site of operation must be protected from rain and other water sources. 3. Storage of gas cylinders Liquid gas cylinders should never be stored in unventilated areas or below ground (funnel-shaped holes). Avoid direct sunlight. The gas cylinder should not be exposed to temperatures in excess of 50°C. 4. Installation To be installed horizontally on a smooth, firm or any other appropriate surface.
After sufficient cooling (approximately 5 hours), the thermostat position can be set to a lower temperature, between 2-5. The thermostat will now automatically regulate the set temperature. To turn off (Fig. 1) Turn thermostat knob (A) anticlockwise to position '0' (a slight resistance will be felt just before this position). Pull out mains plug. 7. D/C operation Do not use any additional form of energy (mains/gas).
8. Liquid gas operation Do not use any additional form of energy (mains/battery). The unit must not be connected to town or natural gas pipelines. It is only suitable for use with propane/butane gas (e.g. Calor Gas, Camping Gaz, Caravangas, etc). The specified gas-connection pressure is given in mbar on the type plate (see back of appliance).
and water solution over them and watching for bubbles, which would indicate a leak. After testing dry off traces of detergent. For your safety Do not check for leaks with a naked flame! Do not smoke while checking for leaks! 10. Gas equipment system (Fig. 1) This consists of a control knob (B) with built-in safety pilot, a burner with igniter plug and a piezo-gas igniter (E).
12. Shutting down gas operation 1. Close gas cylinder or pressure regulating valve. 2. Turn knob (B) clockwise to the off position. 13. Food and drink storage Foodstuffs and drinks should always be sealed when stored in the cooling unit. Thus, changes in taste and smell are avoided. Food and drink should be so placed in the cooler so as to allow air to circulate freely. Do not place hot food or drinks in the cooler! Under no circumstances should inflammable liquids and/or gases be stored in the cooler.
16. Maintenance Changing the gas filter: the cellulose gas filter is situated at the back in the gas connection piece. When it becomes necessary to replace the gas filter, remove the filter from the duct and replace it with a new one. Any other maintenance and repair works, especially those relating to the cooling aggregate and the gas-burner system, may only be undertaken by authorized customer service points. 17.
was a too large a quantity of food or drink stored at any one time? Food and drink should be so stored as to allow free air circulation. Do not use paper or plastic plates. Always keep containers for liquids sealed. Indicate the type of defect, type of appliance, product number and serial number (on the type plate at the back of the unit). We accept responsibility for the perfect condition of the unit, the guarantee being in accordance with our guarantee conditions. 18.
Fig.
seal Fig 2 seals Fig 3 11
Printed by Océ Hungária Kft. 2006. 05. 31.