PSB150 Technical data
19
Dimensions
Absorption to Equalizing or Float condition:
– Charging current drops to:
– Absorption charging timed out:
0.5 A ± 0.1 A
4 hours
Equalization charging active
(only for WET or CALCIUM battery):
– Battery voltage discharged to less than:
– Automatic equalizing charging periodical:
– Equalization charging voltage at 25 °C:
– Equalization charging timer timed out:
10 ± 0.2 Vg
28 days
15.5 ± 0.2 Vg
2 hours
Float charging voltage at 25 °C:
– For LTO and LiFePO4 battery:
– For GEL, AGM, WET, CALCIUM battery:
13.4 ± 0.2 Vg
13.6 ± 0.2 Vg
Battery temperature compensation
coefficient:
–24 mV/°C
Temperature compensation range: –20°C to +50 °C
Operating temperature: –25 °C to +50 °C
Enclosure: IP65
310
1210
908
2233
a
PSB150W-IO-AUS.book Seite 19 Donnerstag, 2. August 2018 9:15 09