Instruction Manual

EN
Installing the device PI8022, PI8023
14
6.4 Connecting the device to the power supply (PI8023)
Connect the device as shown (fig. 8).
Add a 1 A fuse in the plus line near the battery.
6.5 Testing the device
Ignite all burners both individually and concurrently to ensure correct operation
of gas valves, burners and ignition.
Turn gas taps to low flame position and observe the stability of the flame for each
burner individually and concurrently.
Depending on the type of gas used, the appearance of the flame is as follows:
Propane: Flame with blue centre and well-defined contour
Butane: Flame with light yellow tips when igniting the burner, gradually
intensifying as the burner heats
Ensure correct operation of the flame failure protection.
12 V
1 A
2 x 0,5 mm
2
red
black
d200 cm
8
DometicPI8002-PI8022-PI8023_IOM_4445103105_APAC(en)_xxxx-xx-xx.book Seite 14 Mittwoch, 20. Januar 2021 10:10 22