User Manual
EN
Charging PBC110
12
6.2 Charge rate
The following maximum capacities are to be used as a general guide:
6.3 Settings
➤ Using the battery type selector (4) choose the battery type to be used, see
fig. 2, page 10.
➤ Using the charge rate selector (5) choose the charge rate to be used, see fig. 2,
page 10.
7Charging
7.1 Electrolyte level check and precharge check
➤ Only for Flooded or WET battery: Check the battery electrolyte level.
If necessary, remove the vent caps and add distilled water so the levels are half-
way between the upper and lower fill lines.
➤ Check the battery label for battery type and capacity. Only charge 12 V lead acid
(GEL, WET, AGM) or LiFePO4 batteries.
➤ Ensure that the battery charger is not connected to mains power.
7.2 Connect the battery charger to the battery
!
WARNING!
• Only use the device indoor. Do not expose the battery charger to rain,
snow and liquids.
• Explosive gases may escape from the battery during charging. Pro-
vide good ventilation to prevent flames and sparks.
• When connecting to the battery, the battery charger must not be con-
nected to mains power.
Setting Battery capacity/Charging Battery capacity/Maintaining
2 A 6 – 20 Ah 6 – 20 Ah
5 A 21 – 50 Ah 21 – 60 Ah
10 A 51 – 200 Ah 61 – 240 Ah