User Manual

EN
Charging PBC110
12
6.2 Charge rate
The following maximum capacities are to be used as a general guide:
6.3 Settings
Using the battery type selector (4) choose the battery type to be used, see
fig. 2, page 10.
Using the charge rate selector (5) choose the charge rate to be used, see fig. 2,
page 10.
7Charging
7.1 Electrolyte level check and precharge check
Only for Flooded or WET battery: Check the battery electrolyte level.
If necessary, remove the vent caps and add distilled water so the levels are half-
way between the upper and lower fill lines.
Check the battery label for battery type and capacity. Only charge 12 V lead acid
(GEL, WET, AGM) or LiFePO4 batteries.
Ensure that the battery charger is not connected to mains power.
7.2 Connect the battery charger to the battery
!
WARNING!
Only use the device indoor. Do not expose the battery charger to rain,
snow and liquids.
Explosive gases may escape from the battery during charging. Pro-
vide good ventilation to prevent flames and sparks.
When connecting to the battery, the battery charger must not be con-
nected to mains power.
Setting Battery capacity/Charging Battery capacity/Maintaining
2 A 6 – 20 Ah 6 – 20 Ah
5 A 21 – 50 Ah 21 – 60 Ah
10 A 51 – 200 Ah 61 – 240 Ah