13.1 Environment correction
Factor of environment correction C:
I
14 Copyright
© 2020 Dometic Group. The visual appearance of the contents of this manual is pro-
tected by copyright and design law. The underlying technical design and the prod-
ucts contained herein may be protected by design, patent or be patent pending.
The trademarks mentioned in this manual belong to Dometic Sweden AB. All rights
are reserved.
Altitude (m) Ambient temperature °C
25 30 35 40 45
0 1 0.98 0.96 0.93 0.90
500 0.93 0.91 0.89 0.87 0.84
1000 0.87 0.85 0.82 0.80 0.78
2000 0.75 0.73 0.71 0.69 0.66
3000 0.64 0.62 0.60 0.58 0.56
4000 0.52 0.52 0.50 0.48 0.46
NOTE
• Relative humidity 60% correction factor C -0.01;
• Relative humidity 80% correction factor C -0.02;
• Relative humidity 90% correction factor C -0.03;
• Relative humidity 100% correction factor C -0.04;
• Example: Generator rated power PN =1.8kVA, Altitude:1000m,
Ambient temperature: 35° C, Relative humidity: 80%,
•Actual power P:
P=PN*(C-0.02)=1.8*(0.82-0.02)=1.44kVA