Transport and storage PGE121
46
Turn the fuel tap (fig. B 1) to the “OFF” position.
Turn the fuel cap vent lever to “OFF” position.
Engine
While engine is still warm, drain oil from crankcase. Refill with the recommended
new oil.
Remove spark plug and pour about 15ml (
1
/
2
ounce) of engine oil into the cylin-
der through spark plug hole.
Cover the spark plug hole with a rag.
Pull the starting rope several times to coat the cylinder walls with engine oil.
Install and tighten the spark plug.
Pull the Starter Grip until you feel compression, then stop pulling.
This prevents the cylinder and valves from rusting.
Clean the generator outer surfaces.
Check that cooling air slots and openings on generator are open and unob-
structed.
Store the unit in a clean, dry place.
If possible, store the unit indoors and cover it to give protection from dust and dirt.