Transport and storage PGE121
46
➤ Turn the fuel tap (fig. B 1) to the “OFF” position.
➤ Turn the fuel cap vent lever to “OFF” position.
Engine
➤ While engine is still warm, drain oil from crankcase. Refill with the recommended
new oil.
➤ Remove spark plug and pour about 15ml (
1
/
2
ounce) of engine oil into the cylin-
der through spark plug hole.
➤ Cover the spark plug hole with a rag.
➤ Pull the starting rope several times to coat the cylinder walls with engine oil.
➤ Install and tighten the spark plug.
➤ Pull the Starter Grip until you feel compression, then stop pulling.
✓ This prevents the cylinder and valves from rusting.
➤ Clean the generator outer surfaces.
➤ Check that cooling air slots and openings on generator are open and unob-
structed.
➤ Store the unit in a clean, dry place.
If possible, store the unit indoors and cover it to give protection from dust and dirt.