Fill to the upper limit of the oil filler neck with the recommended oil, see chapter
“Technical data” on page 48.
If the wet line on the oil level indicator (fig. r 3, page 34) is between "L" posi-
tion and "H" position, the oil level is OK. If the oil is below "L" position, the oil
level is too low.
Fill to the upper limit of the oil level indicator with the recommended oil, see
chapter “Technical data” on page 48.
Tighten the dipstick (fig. r 2, page 34) and reinstall the oil maintenance cover
(fig. r 1, page 34).
Change engine oil
I
Place the generator on a flat level surface.
Make sure, the engine switch (fig. 6 8, page 12) is in “OFF“ position.
Before tipping the engine to drain the used oil, drain the fuel in the carburetor to
prevent fuel leakage, see chapter “Long time storage >6 month” on page 43.
Turn the fuel tap (fig. 6 1, page 12) to “OFF“ position and close the fuel cap
tightly.
Make sure the fuel cap vent lever is turned to position “OFF“ to reduce the risk of
fuel leakage.
Open the oil maintenance cover (fig. s 1).
Place a suitable oil pan under the oil filler neck (fig. s 3) to catch the used oil.
NOTE
Drain the engine oil while the engine is warm.
s