Product Manual

EN
Operating the generator PGE121
28
Start AC parallel
!
A
Disconnect all electrical devices from both generators.
Connect the Parallel Kit (fig. h 2, page 27) between the parallel terminals of the
two generators.
Start the two generators and make sure the ready LED (fig. h 4, page 27)
comes on.
Plug the electrical device into the power socket of the Parallel Kit
(fig. h 2, page 27).
Turn on the electrical device to use.
Stop AC parallel
Disconnect all electrical devices from the Parallel Kit (fig. h 2, page 27).
Stop the engine, see page 24.
Allow the generator to cool down before transporting or storing.
WARNING! HIGH VOLTAGE
Don't operate with wet hands.
Don't allow generator to be operated by children.
Make sure to ground the generator.
NOTICE!
Don‘t connect the generator with any other generator than a second
PGE121.
Don‘t connect the Parallel Kit when the engine is running.
Don‘t use the Parallel Kit for single operation.
Make sure the electrical appliance rated power does not exceed the
total rated power of the two generators.
If an appliance begins to operate abnormally turn it off immediately.
The ECO switch must be in the same position on both generators.
Most motorized appliances require more than the rated
wattage for start-up. Therefore it is normal if the Overload LED comes
on shortly and goes off after a few seconds.