Operating the generator PGE121
28
Start AC parallel
!
A
➤ Disconnect all electrical devices from both generators.
➤ Connect the Parallel Kit (fig. h 2, page 27) between the parallel terminals of the
two generators.
➤ Start the two generators and make sure the ready LED (fig. h 4, page 27)
comes on.
➤ Plug the electrical device into the power socket of the Parallel Kit
(fig. h 2, page 27).
➤ Turn on the electrical device to use.
Stop AC parallel
➤ Disconnect all electrical devices from the Parallel Kit (fig. h 2, page 27).
➤ Stop the engine, see page 24.
➤ Allow the generator to cool down before transporting or storing.
WARNING! HIGH VOLTAGE
• Don't operate with wet hands.
• Don't allow generator to be operated by children.
• Make sure to ground the generator.
NOTICE!
• Don‘t connect the generator with any other generator than a second
PGE121.
• Don‘t connect the Parallel Kit when the engine is running.
• Don‘t use the Parallel Kit for single operation.
• Make sure the electrical appliance rated power does not exceed the
total rated power of the two generators.
• If an appliance begins to operate abnormally turn it off immediately.
• The ECO switch must be in the same position on both generators.
• Most motorized appliances require more than the rated
wattage for start-up. Therefore it is normal if the Overload LED comes
on shortly and goes off after a few seconds.