3108705.744 INSTRUCTIONS USA SERVICE OFFICE Dometic Corp. 509 So. Poplar St. LaGrange, IN 46761 (260) 463-4858 POWER VENTILATOR ASSEMBLY PART NO. 3108705.744 For Two Door Absorption Refrigerators CANADA Dometic Dist. 866 Langs Dr. Cambridge, Ontario CANADA N3H 2N7 (519) 653-4390 PATENT NO. 5355693 For Service Center Assistance Call: 800-544-4881 INSTALLATION INSTRUCTIONS Form No. 3309090.003 3/04 (French 3309091.001) ©2004 Dometic Corporation LaGrange, IN 46761 1 Power Ventilator Asm. 3108705.
3108705.744 INSTRUCTIONS SAFETY INSTRUCTIONS ! WARNING These instructions must be read and understood before installation of this kit. This kit must be installed by a Dometic Service Center or a qualified service technician. Modification of this product can be extremely hazardous and could result in personal injury or property damage. This manual has safety information and instructions to help users eliminate or reduce the risk of accidents and injuries.
108705.744 INSTRUCTIONS Select the option which suits your specific application. Follow Power Ventilator Assembly instructions for that specific application. OPTION 1: Through-The-Floor Vent Installation with Upper Roof Vent OPTION 2: Upper and Lower Plastic Side Vents OPTION 3: Side-By-Side Refrigerator with Upper and Lower Plastic Side Vents OPTION 1: Through-The-Floor Vent Installation with Upper Roof Vent FIG.
3108705.744 INSTRUCTIONS Note: Route wire away from sharp edges and hot surfaces. d. Remove the fuse from fuse holder and store in safe location for later installation. e. Install mounting brackets to ventilator fan using the #8 x 2" screws provided. See FIG. 1B. f. Install refrigerator according to installation instructions supplied with refrigerator. Note: Completion of the Power Ventilator Assembly installation will be made through the rear access panel. See Table 1. g.
3108705.744 INSTRUCTIONS TABLE 2 (Dimensions in Inches) Model Min. Dim. No. RM3862 NDR1062 A 61 61 Min. Dim. B 24-5/8 24-5/8 Min. Dim. Max. Dim. C 5-1/8 5-1/8 C 8 8 Max. Dim. D* 3-1/2 3-1/2 Max. Dim. E 1 1 F 45-1/2 45-1/2 C Air Direction CENTER OF REFRIG FIG.
3108705.744 INSTRUCTIONS e. Attach red wire from fan motor to one terminal of fan limit switch. Note: Route wire, as shown in FIG. 3, away from s h a r p edges and hot surfaces. f. Attach red wire with fuse holder to the remaining terminal of fan limit switch. Route the wire along side of refrigerator as shown in FIG. 3. Note: Route wire away from sharp edges and hot surfaces. g. Remove fuse from fuse holder and store in safe location for later installation. h.
3108705.744 INSTRUCTIONS FIG. 3 * When dimension "D" exceeds 1", it may be necessary to add baffle/s above lower access vent, as shown, for more efficient operation in warm temperatures.