User manual

7
CERTIFIED INSTALLATION
Certified installations require one roof vent and one lower
side vent.
For Certified Vent System Kits see page 14.
For further information contact your dealer or distribu-
tor.
METHODS OF INSTALLATION
The method of installation is shown in FIG. 9. It is es-
sential that all maximum or minimum dimensions are
strictly maintained as the performance of the refrigera-
tor is dependent on adequate flow of air over the rear of
the refrigerator.
NOTE: The upper vent should be centered over the
condenser coil at the back of the refrigerator.
VENTILATION HEIGHTS
CLEARANCES
Minimum clearances in inches to combustible materials
are:
G: Top 0
K: Side 0
L: Bottom 0
M: Rear 0
N: See NOTE: Clearance N below.
NOTE: Clearance M is between the rearmost part of
the refrigerator and the wall behind the refrigerator.
NOTE: Clearance N is the distance between the bot-
tom of the lower vent to the roof material. For ventilation
height, see table VENTILATION HEIGHTS
See Figures 9, and 10.
LOWER VENT CUTOUT
13-5/8
28-5/8
FIG. 9
Ventilation
height
Condenser
K
G
K
N
L
M
NOTE: Wood Strip
MUST be in place
FIG. 10
Installation with roof Minimum ventilation
vent and lower side vent heights in:
Refrigerator Inches mm
NDR 1292-S 65 1651
NDR 1292-B