The status LED (fig. 1 2, page 3) displays the following conditions:
11 Guarantee
The statutory warranty period applies. If the product is defective, please
contact the manufacturer's branch in your country (see the back of the
instruction manual for the addresses) or your retailer.
For repair and guarantee processing, please include the following docu-
ments when you send in the device:
z A copy of the receipt with purchasing date
z A reason for the claim or description of the fault
12 Disposal
Place the packaging material in the appropriate recycling waste bins
wherever possible.
M
If you wish to finally dispose of the product, ask your local recycling
centre or specialist dealer for details about how to do this in
accordance with the applicable disposal regulations.
Display Cause Remedy
Green, constantly lit The device is functioning.
Red, quickly flashing Input voltage is too high. Check the input voltage.
Reduce the input voltage.
Red, slowly flashing The input voltage is too low. Charge the battery.
Check cables and contacts.
Red, occasionally flashing Overheating Ensure better ventilation.
Make certain that the ventila-
tion slots are not covered.
Lower the ambient tempera-
ture.
Red, constant light Short circuit or electrical
wiring error
Check electrical wiring.
Excessive load Reduce the load.