Operating instructions
EN
SinePower Connecting the inverter
27
7 Connecting the inverter
a
Caution
The cable between the battery and the inverter may not exceed a
maximum length of 2 m.
7.1 Connecting the MSP 162 and MSP 164
The connection is made via a plug that is connected to a 12 V vehicle socket
(for MSP 162) and a 24 V vehicle socket (for MSP 164).
The middle pin of the plug must be connected to the positive wire (fig. 1 6,
page 3) and the two side brackets of the plug must be connected to the neg-
ative wire (fig. 1 7, page 3).
a
Caution
Make sure that the plug is firmly connected in the vehicle socket. If
the connection is loose, the plug may heat up.
e
Caution
The rating of the vehicle socket, the supply cable, and the fuse
must be at least 15 amps. Do not put in a fuse with a higher rating.
7.2 Connecting the MSP 352 and MSP 354
e
Warning
Never use the inverter on vehicles where the positive terminal of
the battery is connected to the chassis.
z Connect the inverter to the chassis or earth.
z Only use copper cables.
z Keep the cables as short as possible.
z Fit a 50 A cable fuse in the positive cable as close to the vehicle battery
as possible.
_MSP160_MSP350.book Seite 27 Freitag, 9. September 2011 4:44 16