Operation Manual
10
FINNISH
MALAYSIAN
RUSSIAN
DIAGNOSTICS Display of the current status of the appliance
(only for service purposes).
PARAMETERS Display of the current setting of all parameters
SSttaattuuss-- aanndd WWaarrnniinngg mmeessssaaggeess
• The electronics generate various status or warning messages depending on the
setting or the condition of the appliance.
• If one or several messages are to be displayed at the same time in one line, these
messages appear alternately on the display.
DOOR OPEN This message appears as soon as the door of the appliance is
opened. If the door is not closed again after a preset time, an alarm is
triggered. This alarm is not entered in the history list.
The message or the alarm disappears as soon as the door is
closed.
HISTORY This message indicates that a new entry has been made in the alarm
history list. The message disappears as soon as the history has been
displayed once with the function “SHOW HISTORY”.
ALARM TEST Appears during an alarm test. The message disappears as soon as the
test has finished.
AMB ..°C If an ambient temperature sensor is connected to the appliance and the
display in the EXTRA menu activated ( - EXTRA - AMBIENT PROBE),
this message appears followed by the currently measured ambient
temperature in the display.
REG ..°C If the display of the regulating sensor is activated in the EXTRA menu
( - EXTRA - ADD. PROBE - REGULATION) this message appears
followed by the currently measured control temperature in the display.
SERVICE If the appliance has been running for a preset time this message
appears on the display to indicate that a cleaning or maintenance
procedure is required. The message can be cancelled with the “HIDE
SERVICE WARNING” function in the SETTINGS menu.
HIGH AMBIENT TEMP. If an ambient temperature sensor is connected to the appliance and if
this value rises above a given value this message appears on the
display. The appliance will however function normally. The maximum
value stored in the electronics depends on the temperature class of the
appliance in question and cannot be changed.
LOW AMBIENT TEMP. analogous to “HIGH AMBIENT TEMP.” however with minimum value.