Harrier series Technical data
9 Technical data
Contains fluorinated greenhouse gases. Hermetically sealed equipment.
Harrier Lite
HL36H401RI,
HL36H401RIY
Harrier Plus
HP36H401RI,
HP36H401RIY
Compressor cooling capacity: 3600 W
Cooling capacity based on ISO 5151: 2413 W 3028 W
Heating capacity based on ISO 5151: 2421 W 3017 W
Rated input voltage: 220 Vw to 240 Vw/ 50 Hz
Rated current cooling: 7.5A 6.9A
Rated current heating 6.1 A 5.9 A
Required fuse: 10 A
Operating temperature range: –2 °C to +52 °C
Refrigerant: R-410A
Refrigerant quantity: 0.650 kg 0.750 kg
CO
2
equivalent: 1.357 t 1.566 t
Global warming potential (GWP): 2088
Protection class (outdoor unit): IPX4
Suggested max. vehicle length
(with insulated walls): <6 m >7.5 m
Dimensions L x W x H
(height above vehicle roof): 997 x 665 x
240 mm
1070 x 750 x
280 mm
Weight: 37kg 44kg
Inspection/certification: