Installation Guide

21
EN
Harrier series Installation
Fasten the ADB to the ceiling through to the roof air conditioner with the
4 bolts supplied.
See fig. h
A
Tighten the screws using a torque spanner and a fastening torque of
2.5 Nm ±0.3 Nm.
8.5.5 Communication cable
Connect the communication 4 pin plug into the socket on the side of the
display (2) in the ADB.
Ensure the cable is located into the small opening away from the filter area.
Secure excess cable into the holders.
Push the filter back fully in.
NOTICE! Risk of damage
Tighten to the specified torque. Do not overtighten!
A
2.5±0.3 Nm
h
Harrier-Lite_INM.book Seite 21 Donnerstag, 30. April 2020 3:45 15