EN Air conditioning roof unit Operating manual . . . . . . . . . . . . . . .
Dometic Harrier Inverter 1 1 4 3 2 2 1 10 2 9 3 8 4 7 5 6 3
Dometic Harrier Inverter 3 1 2 13 12 11 10 3 4 5 6 7 8 9 4
Dometic Harrier Inverter 4 1 5 1 2 5
Dometic Harrier Inverter 6 1 1 7 750 1070 520 6 66 280 30 – 60 620 500
Dometic Harrier Inverter Please read this manual carefully before installing and using the device, and keep it in a safe place. If you sell the device, pass on this instruction manual to the buyer. Table of contents 1 Explanation of symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2 Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2.1 General safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2.
Explanation of symbols Dometic Harrier Inverter 12 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 13 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 14 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 1 Explanation of symbols ! ! A I WARNING! Safety instruction: Failure to observe this instruction can cause fatal or serious injury.
Dometic Harrier Inverter 2 Safety instructions Safety instructions The manufacturer accepts no liability for damage in the following cases: Damage to the product resulting from mechanical influences and excess voltage Alterations to the product without express permission from the manufacturer Use for purposes other than those described in the operating manual In particular, the manufacturer will not be liable for any consequential damage, especially consequential damage caused by failure of the ro
Safety instructions Dometic Harrier Inverter Do not use the roof air conditioner near flammable fluids or in closed rooms. Make sure no combustible objects are stored or installed near the air outlet. A distance of at least 50 cm must be kept. Do not reach into air outlets or insert any foreign objects in the roof air conditioner. Do not undo the upper cover of the roof air conditioner in the event of a fire. Use approved extinguishing agents instead. Do not use water to extinguish fires.
Dometic Harrier Inverter 3 Target group for this manual Target group for this manual This operating manual is for the user of the roof air conditioner.
Technical description 6 Dometic Harrier Inverter Technical description The roof air conditioner supplies the interior with cool or warm dehumidified air without dust and dirt. LED lamps integrated in the air outlet unit provide pleasant lighting. The roof air conditioner is operated with the remote control. I NOTE The roof air conditioner can lower the temperature within the vehicle to a certain level.
Technical description Dometic Harrier Inverter 6.2 Control panel The control panel is at the air outlet unit of the roof air conditioner (fig. 2, page 3). It contains the following control and display elements: No. 1 Explanation Button P Switches the roof air conditioner on, off or to stand-by mode with status indicator: Off: The roof air conditioning is switched off. Red light: The roof air conditioner is in stand-by mode. White light: The roof air conditioning is switched on.
Technical description 6.3 Dometic Harrier Inverter Remote control All settings of the device (e. g. temperature settings, timer programming) are transmitted to the roof air conditioner by remote control. The following control and display elements are available on the remote control (fig. 3, page 4) : No.
Technical description Dometic Harrier Inverter No. Explanation 10 Button Switches the front oscillation vent On/Off. 12 Button Switches the light of the roof air conditioner on or off. 13 Button Selects the fan setting 6.4 Air conditioning modes The roof air conditioner has the following air conditioning modes: Air conditioning mode Display message Explanation Automatic The air conditioner automatically maintains the temperature between 20 °C and 25 °C by heating or cooling as needed.
Before initial use 6.5 Dometic Harrier Inverter Additional functions The roof air conditioner has the following additional functions: Additional function Timer Sleep 7 Display message Explanation 01.5 h The roof air conditioner is switched on at the specified time between 0.5 to 24 hours in the future. 23.5 h The roof air conditioner is switched off at the specified time between 0.5 to 24 hours in the future. The fan and compressor speeds are reduced to minimum to reduce noise.
Dometic Harrier Inverter Operating the roof air conditioner 8 Operating the roof air conditioner 8.1 Basic notes on operation The roof air conditioner has three operating modes: Operating mode Features Off The roof air conditioner is switched off. The remote control is inactive. Stand-by The roof air conditioner is ready for operation and can be switched on with the remote control. The lights are available. On The roof air conditioner is conditioning the air in the interior.
Operating the roof air conditioner 8.3 Dometic Harrier Inverter Hint for improved use The following hints will optimise the performance of your roof air conditioner: Improve the heat insulation of your vehicle by sealing gaps and hanging reflective blinds or curtains on your windows.
Dometic Harrier Inverter 8.6 Operating the roof air conditioner Setting the temperature Cooling Mode In the “Cooling” ( ) and “Dehumidifying” ( ) modes you can specify a temperature between 16 °C and 30 °C via the remote control. ➤ Use the + or – button to select the desired temperature. ✓ The roof air conditioner confirms the receipt of the values with a beep. ✓ The temperature is set on the roof air conditioner.
Operating the roof air conditioner Dometic Harrier Inverter ➤ Before programming the timer, select the air conditioning mode and all required values (e.g. temperature). Setting the on and off times ➤ Press the TIMER button once. ✓ The ON symbol ( 01.5 h ) flashes on the display of the remote control. ➤ Use the + or – button to set the time when the roof air conditioner is to switch on. ➤ Press the TIMER button to transmit the value to the roof air conditioner. ✓ The OFF symbol ( 23.
Dometic Harrier Inverter 8.11 Cleaning the roof air conditioner Replacing the remote control batteries Replace the batteries if you notice the range of the remote control reduced. I NOTE The display may remain bright. The battery compartment is on the back of the remote control. ➤ Gently lift the lid of the battery compartment via the clip and remove it. ➤ Insert the new batteries (2 x type AAA) in the remote control as indicated in the battery compartment.
Maintenance of the roof air conditioner Dometic Harrier Inverter 10 Maintenance of the roof air conditioner ! WARNING! Any other maintenance work to that which is described here may only be carried out by qualified personnel who are familiar with the risks involved when handling refrigerant and air conditioning systems as well as the relevant regulations. Interval Inspection/maintenance Regularly Check the condensation water drainage: ➤ Check whether the condensation water drainage channels (fig.
Troubleshooting Dometic Harrier Inverter 11 Troubleshooting Problem Cause Remedy Icing sensor has tripped. Roof air conditioner constantly switches itself off. Outer temperature is too low or all air nozzles are closed. Not cooling well The roof air conditioner is not set to cooling. ➤ Set the roof air conditioner to cooling. The ambient temperature is above 52 °C. The roof air conditioner is only designed for ambient temperatures of up to 52 °C.
Warranty Dometic Harrier Inverter Problem Cause Remedy Water enters the vehicle The condensation water drainage openings are clogged up. ➤ Clean the drainage openings for condensation water. The seals are damaged. ➤ Contact an authorised service agent or Dometic. No supply voltage (240 Vw) connected. ➤ Check the power supply. The voltage is too low (under 200 Vw). ➤ Contact an authorised service agent or Dometic. Roof air conditioner does not switch on. The voltage converter is defective.
Dometic Harrier Inverter 13 Disposal Disposal Regulations for environmental safety and correct disposal All organisations must apply a set of procedures to identify, evaluate and control the influence that their activities (manufacturing, products, services, etc.) have on the environment.
Disposal Dometic Harrier Inverter For more information on correct dismantling of our products please refer to the recycling handbooks at www.dometic.com. ➤ Place the packaging material in the appropriate recycling waste bins wherever possible. ➤ When in operation or undergoing repairs and maintenance work, make sure that the refrigerant circuit is not damaged and refrigerant cannot escape. It acts as a greenhouse gas and should not be allowed into the environment.
Technical data Dometic Harrier Inverter 14 Technical data Dometic Harrier Inverter Item no.: CK36H401RI Compressor rated capacity: 3675 W Cooling capacity based on ISO 5151: 3124 W Heating capacity based on ISO 5151: 2827 W Rated input voltage: 230 Vw / 50 Hz Power consumption in cooling mode: 6.5 A Power consumption in heating mode: 5.2 A Operating temperature range: Refrigerant: Blower: Suggested max.
AUSTRALIA Dometic Australia Pty. Ltd. 1 John Duncan Court · Varsity Lakes QLD 4227 1800 212121 · +61 7 55076001 Mail: sales@dometic.com.au AUSTRIA Dometic Austria GmbH Neudorferstraße 108 A-2353 Guntramsdorf +43 2236 908070 +43 2236 90807060 Mail: info@dometic.at ITALY Dometic Italy S.r.l. Via Virgilio, 3 I-47122 Forlì (FC) +39 0543 754901 +39 0543 754983 Mail: vendite@dometic.