EN Air conditioning roof unit Installation Manual. . . . . . . . . . . . . . .
Dometic Harrier Inverter Explanation of symbols Please read this instruction manual carefully before installation and start-up, and store it in a safe place. If you pass on the device to another person, hand over this instruction manual along with it. Table of contents 1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2 Safety and installation instructions. . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety and installation instructions I Dometic Harrier Inverter NOTE Supplementary information for operating the product. ➤ Action: This symbol indicates that action is required on your part. The required action is described step-by-step. ✓ This symbol describes the result of an action. Fig. 1 5, page 3: This refers to an element in an illustration. In this case, item 5 in figure 1 on page 3.
Dometic Harrier Inverter 2.1 Handling the device ! WARNING! Safety and installation instructions Installation and repair of the roof air conditioner may only be carried out by qualified personnel who are familiar with the risks involved and the relevant regulations. Inadequate repairs may cause serious hazards. For repair service, please contact the service centre in your country (addresses on the back page). Electrical devices are not toys.
Safety and installation instructions A Dometic Harrier Inverter NOTICE! Only use the device as intended. The roof air conditioner is not suitable for use in agricultural or construction vehicles. Do not make any alterations or conversions to the device. Never drive through automatic car washes when the roof air conditioner is mounted. If faults occur in the refrigerant circuit, the system must be checked by a specialist company and repaired properly.
Dometic Harrier Inverter 3 Target group for this instruction manual Target group for this instruction manual The instructions in this manual are intended for qualified personnel at workshops who are familiar with the guidelines and safety precautions to be applied. 4 Scope of delivery No. in fig.
Intended use 6 Dometic Harrier Inverter Intended use The Dometic Harrier inverter roof air conditioner can condition the interior of campers and caravans with cool or warm dehumidified air. The roof air conditioner is not suitable for installation in construction machines, agricultural machines or similar equipment. It will not work properly if exposed to strong vibrations. Do not operate the roof air conditioner if the ambient temperature is above 52 °C.
Dometic Harrier Inverter Installation 8 Installation ! CAUTION! Beware of injury The roof air conditioner may only be installed by qualified personnel. The following information is intended for technicians who are familiar with the guidelines and safety precautions to be applied. 8.1 Note on installation Read this installation manual completely before installing the roof air conditioner.
Installation Dometic Harrier Inverter Note on transport Always have someone help you carry the roof air conditioner. Always lift the roof air conditioner to move it and never drag it over the roof (fig. 2 A). Do not use the rear or side ventilation slots to lift it (fig. 2 B). Note on installation location Before installing the roof air conditioner, check whether any vehicle components could be damaged by the installation of the roof air conditioner (such as lamps, cupboards, doors).
Dometic Harrier Inverter Installation Note on electrical system Only a qualified electrician should connect the roof air conditioner to the electrical power. Check that the voltage specification on the type plate is the same as that of the power supply. Do not lay cables which are loose or bent next to electrically conductive material (metal). Install an all-pole switch with a contact opening width of at least 3 mm on the installation side.
Installation Dometic Harrier Inverter 8.3 Installing in an existing opening I NOTE Existing roof openings in accordance with fig. 3 are suitable for installing the roof air conditioner. Dispose of all waste material, glue, silicone and seals separately. Observe the disposal guidelines. The manufacturer only assumes liability for parts included in the scope of delivery. The validity of the warranty expires if the device is installed together with third-party parts. See fig.
Installation Dometic Harrier Inverter See fig. 9 ➤ Make an opening on one side in order to feed through the electrical power supply cable. ➤ Feed the 240 Vw cable through the opening into the vehicle interior. 8.5 Installing the roof air conditioner ADB A NOTICE! Risk of damage Observe the structural strength of the roof of the vehicle. The roof of the vehicle must be able to bear the weight of the roof air conditioner.
Installation I Dometic Harrier Inverter NOTE For the thicker roof seal refer to the instructions included with the seal kit. ➤ Clip the transition duct (3) in place over the duct insert (1). I NOTE Ensure the transition duct or seal is located correctly over the duct insert, otherwise the performance of the unit may be affected. ➤ Raise the ceiling plate (5) into position and clip the transition duct into place. ➤ The 4 bolts (4) are used to clamp the rooftop unit and ceiling plate into place.
Troubleshooting Dometic Harrier Inverter 8.6 Installing the ADB cover See fig. c ➤ Place the ADB cover over the ceiling plate. See fig. d ➤ Fix the ADB cover using the 4 screws (2) provided. ➤ Install the screw covers (1) over the opening. ➤ Insert the 2 air filter elements (3). ➤ Enter the new vehicle height and weight in the vehicle documents (if required). 9 Troubleshooting Problem Cause Remedy Roof air condiIcing sensor has tripped. tioner constantly switches itself off.
Troubleshooting Dometic Harrier Inverter Problem Cause Remedy Not heating well The roof air conditioner is not set to heating. ➤ Set the roof air conditioner to heating. The ambient temperature is below –2 °C. The roof air conditioner will only heat at ambient temperatures above –2 °C. The temperature set is lower than the room temperature. ➤ Select a higher temperature. One of the temperature sensors is defective. ➤ Contact an authorised service agent or Dometic.
Disposal Dometic Harrier Inverter Problem Cause Remedy Remote control does not register The remote control is not pointing towards the ADB display. ➤ Point the remote control towards the ADB display. The batteries in the remote control are low. Note: The display of the remote control will still be bright even if the batteries are low. ➤ Replace the batteries in the remote control.
Disposal Dometic Harrier Inverter During operation and maintenance ensure that any waste pollutant products (oil, grease, etc.) are disposed of correctly. Keep noise levels down to reduce noise pollution. For more information on correct dismantling of our products please refer to the recycling handbooks at www.dometic.com. ➤ Place the packaging material in the appropriate recycling waste bins wherever possible.
Technical data Dometic Harrier Inverter 11 Technical data Dometic Harrier Inverter Item no.: CK36H401RI Compressor rated capacity: 3675 W Cooling capacity based on ISO 5151: 3124 W Heating capacity based on ISO 5151: 2827 W Rated input voltage: 230 Vw / 50 Hz Power consumption in cooling mode: 6.5 A Power consumption in heating mode: 5.2 A Operating temperature range: Refrigerant: Blower: Suggested max.
AUSTRALIA Dometic Australia Pty. Ltd. 1 John Duncan Court · Varsity Lakes QLD 4227 1800 212121 · +61 7 55076001 Mail: sales@dometic.com.au AUSTRIA Dometic Austria GmbH Neudorferstraße 108 A-2353 Guntramsdorf +43 2236 908070 +43 2236 90807060 Mail: info@dometic.at ITALY Dometic Italy S.r.l. Via Virgilio, 3 I-47122 Forlì (FC) +39 0543 754901 +39 0543 754983 Mail: vendite@dometic.