User manual

10.1. Connecting to electrical mains
The appliance may only be operated from
nominal voltage mains as shown on the data
plate. The appliance mains plug may be connected
to a mains socket earthed in accordance with
regulations.
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
The manufacturer declines any liability should
these safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity
supply voltage is the same as that indicated on the
appliance rating plate.
Only for UK:
The appliance is supplied with a 3 amp plug fitted.
In the event of having to change the fuse in the plug
supplied, a 3 amp ASTA approved (BS 1362) fuse
must be used. Should the plug need to be replaced
for any reason, the wires in the mains lead are
coloured in accordance with the following code:
Green and Yellow: Earth
Blue: Neutral
Brown: Live
The wire coloured green and yellow must be
connected to the terminal marked with the letter „E“
or by the earth symbol or coloured green and
yellow.
The wire coloured blue must be connected to the
terminal „N“ or coloured black.
The wire coloured brown must be connected to the
terminal marked „L“ or coloured red.
Upon completion there must be no cut, or stray
strands of wire present and the cord clamp must be
secure over the outer sheath.
11. Environmental
protection information
The appliance does not contain any CFCs/HCFCs.
Ammonia (natural hydrogen and nitrogen
compound) is used as a refrigerating agent in the
refrigeration unit.
6
Figure 7.
7.1. Automatic defrost function
The first defrosting phase commences 39 hours after
the start and lasts for two hours.
After this, the device operates for 22 hours at a time,
followed by a defrosting period of 2 hours.
8. Interior light
Two light-emitting diodes (A) on an electronic PCB
illuminate the cooling compartment when the door is
opened.
Two sensors (B) control whether the door is open or
not and the LEDs will work accordingly.
Figure 8.
9. Customer service
Before you call a service engineer, carry out the
following simple tests:
When checking all the above points and the
refrigerator is still not working satisfactorily, contact
your nearest service engineer. State the problem,
model, product- and serial-number.
(Details of the model, product- and serialnumber are
to be found on the data label in the top left of the
inside compartment.)
In the event of a fault developing, contact your nearest
Service Centre-see local telephone directory.
10. Putting into operation
Technical data:
B
B
A
A
Model DS 600
Type DS20-60
Gross volume 52,6 litres
Mains operation 240 V (AC)
Input 85W
Energy consumption 0.88 kWh/24h
Climate class SN
Absorber Solution 157g H
2
O + 105 g NH
3