Operating Instructions and Installation Instructions

MAINTENANCE USE
INSTALLATION
20
ENG LISH
MODEL
CU400PE - CU400BPE - CU401PE - CU402PE
CU403PE - CU404PE - CU404PEMW
CU405PEMW - CU407PEMW - CU414PE
RATED VOLTAGE
220-240V~ 50/60Hz 800 W
RATED POWER
FIXTURE
THIS APPLIANCE IS TO BE FIXED AND SECURED TO THE CABINET AS
DESCRIBED IN FIG. 3 – PG. 177.
CONNECTING TO ELECTRICITY SUPPLY
THIS APPLIANCE MUST BE CONNECTED TO A 12 V POWER PACK. THE CIRCUIT
MUST BE FITTED WITH A SAFETY FUSE NOT HIGHER THAN 3 AMP.
WHEN WIRING THE APPLIANCE RESPECT CORRECT POLARITY!
IT IS OF UTMOST IMPORTANCE NEVER TO CONNECT THIS APPLIANCE TO MAINS
VOLTAGE (230 V~) WHICH IRREVERSIBLY DAMAGES APPLIANCE COMPONENTS
AND CREATES A HAZARD TO THE USER.
To connect the appliance use a 1.5 mm
2
double red and black wire and wire to the terminal junction box located at the
rear of the appliance with the wording "+12 V – ". The red terminal is the positive pole and the black terminal is the
negative pole.
LOW VOLTAGE 12 V
This chapter refers only to models with the wording 12 V on the appliance specifications label affixed to the
appliance.
HIGH VOLTAGE 220-240 V~
This charter refers only to the models listed in the below table.
For connecting to the mains power supply use a socket.
If the power supply cable (H05RR-F 3x0,75mm
2
) is damaged, it must be replaced by the manufacturer or by an
authorised service centre or by an electrician with a similar qualification to prevent any hazard or risk.
WHEN CONNECTING DIRECT TO THE MAINS SUPPLY, IT IS NECESSARY TO
INSTALL A CIRCUIT BREAKER WHICH ALLOWS FOR DISCONNECTING AND
ISOLATING THE APPLIANCE FROM THE MAINS IN THE EVENT OF OVERVOLTAGE
III CONFORMING TO INSTALLATION REGULATIONS.
THE SUPPLY CABLE MUST BE POSITIONED SO AS NOT TO REACH IN ANY POINT
ALONG THE CABLE ITSELF A TEMPERATURE OF 75K.
THE PLUG MUST BE EASY TO ACCESS AFTER INSTALLATION.
ALWAYS DISCONNECT ELECTRICAL POWER BEFORE WORKING ON OR SERVICING
THE APPLIANCE.