CT4000-I-AUS.book Seite 1 Dienstag, 6.
CT4000-I-AUS.book Seite 2 Dienstag, 6.
CT4000-I-AUS.book Seite 3 Dienstag, 6. März 2018 1:18 13 CT4000 Please read this instruction manual carefully before installation and first use, and store it in a safe place. If you pass on the product to another person, hand over this instruction manual along with it. Table of contents 1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2.
CT4000-I-AUS.book Seite 4 Dienstag, 6. März 2018 1:18 13 Explanation of symbols CT4000 1 Explanation of symbols ! A I CAUTION! Safety instruction: Failure to observe this instruction can lead to injury. 2 Safety instructions NOTICE! Failure to observe this instruction can cause material damage and impair the function of the product. NOTE Supplementary information for operating the product.
CT4000-I-AUS.book Seite 5 Dienstag, 6. März 2018 1:18 13 CT4000 A Intended use NOTICE! • All components of the system must be installed in frost-free areas. In freezing temperatures, there is a risk of damage caused by frost. • Do not use antifreeze. These agents may damage the cassette toilet. • The operating pressure (water pressure) of the solenoid valve should not exceed 6 bar. The solenoid valve is damaged by excessive pressure.
CT4000-I-AUS.book Seite 6 Dienstag, 6. März 2018 1:18 13 Technical description 4.1 CT4000 Description of the components 1 7 6 8 5 4 3 2 9 1 No. in fig.
CT4000-I-AUS.book Seite 7 Dienstag, 6. März 2018 1:18 13 CT4000 Installing the toilet 5 Installing the toilet 5.1 Installing the service door Model-dependent installation instructions are included with the service door ( Dometic SK4, SK5). I NOTE Prepare the feed-through for the vent hose at the desired location (chapter “Venting the cartridge tank” on page 21). 5.2 Making wall cutouts ➤ Follow the instructions of the installation manual that comes with the service door.
CT4000-I-AUS.book Seite 8 Dienstag, 6. März 2018 1:18 13 Installing the toilet CT4000 5.3 Setting up the toilet A NOTICE! All components of the system must be installed in frost-free areas. In freezing temperatures, there is a risk of damage caused by frost. 3 I NOTE • When installing the toilet in a wet room, the manufacturer recommends that you connect the toilet to the shower tray. • The toilet base is equipped with a protruding collar for receiving the upper edge of the shower tray (fig. 3).
CT4000-I-AUS.book Seite 9 Dienstag, 6. März 2018 1:18 13 CT4000 Installing the toilet CT4050: fig.
CT4000-I-AUS.book Seite 10 Dienstag, 6. März 2018 1:18 13 Installing the toilet CT4000 CTLP4110: fig.
CT4000-I-AUS.book Seite 11 Dienstag, 6. März 2018 1:18 13 CT4000 Installing the toilet CTS4110: fig.
CT4000-I-AUS.book Seite 12 Dienstag, 6. März 2018 1:18 13 Installing the toilet 5.4 CT4000 Installing CT model 7 The detached model CT4050 has no integrated water tank and no console. Set up this model so that the wall behind it can accommodate the control unit of the toilet, the electrical connections and possibly a water tank. It is best if you put a box in front of the room wall (fig. 7).
CT4000-I-AUS.book Seite 13 Dienstag, 6. März 2018 1:18 13 CT4000 Installing the toilet 8 110 50 ➤ Align the toilet according to the service door. ➤ Place the housing base flush with the installation box so that there is a clean transition and no gap.
CT4000-I-AUS.book Seite 14 Dienstag, 6. März 2018 1:18 13 Installing the toilet CT4000 Attaching toilet CT 4050 ➤ Place the toilet in the desired position. 9 6x ➤ Tightly fasten the base plate with six bolts (fig. 9). 38 x ∅4,5 0 ➤ Bolt the toilet housing to the wall (using a maximum of 7 bolts, not included) (fig. 0).
CT4000-I-AUS.book Seite 15 Dienstag, 6. März 2018 1:18 13 CT4000 Installing the toilet Installing the control and operating panel of the CT 4050 toilet Install the control and operating panel in the wall in the immediate vicinity of the toilet at an easily accessible location. a ➤ Use a copy of the 1:1 scale template (fig. a) to make the wall cutout.
CT4000-I-AUS.book Seite 16 Dienstag, 6. März 2018 1:18 13 Installing the toilet CT4000 b 1. 74 R10 60 3. 2. ➤ Prepare an opening in the installation box for the control and operating panel (fig. b). ➤ Connect the electrical cables to the connections of the control and operating panel (chapter “Electrical connection” on page 22).
CT4000-I-AUS.book Seite 17 Dienstag, 6. März 2018 1:18 13 CT4000 Installing the toilet c ➤ Slide in the mobile tank cassette (fig. c). 5.5 Installing models CTLP, CTS These models have a wall connection console. The control and operating panel is integrated in the wall connection console. Set up all models with wall connection console directly against the room wall. A previously attached wall bracket is used to secure the toilet and the wall bracket.
CT4000-I-AUS.book Seite 18 Dienstag, 6. März 2018 1:18 13 Installing the toilet CT4000 e 2 1 ➤ Put the entire toilet module into the desired position in front of the wall bracket. ➤ Lift the toilet and hook the housing into the wall bracket (fig. e). f 6x ➤ Tightly fasten the base plate with six bolts (fig. f).
CT4000-I-AUS.book Seite 19 Dienstag, 6. März 2018 1:18 13 CT4000 g Installing the toilet 2x ➤ Place the two covers over the fastening screws in the base plate (fig. g). ➤ Follow the instructions in (chapter “Connecting the water supply” on page 20). h ➤ Slide in the mobile tank cassette (fig. h).
CT4000-I-AUS.book Seite 20 Dienstag, 6. März 2018 1:18 13 Installing the toilet 5.6 CT4000 Connecting the water supply i 1 2 A NOTICE! • The water supply is connected using a solenoid valve mounted in the toilet housing (fig. i 1). • The operating pressure (water pressure) of the solenoid valve should not exceed 6 bar. • The solenoid valve is damaged by excessive pressure. ➤ Use a spring band hose clamp to attach the freshwater supply hose to the connection socket (fig. i 2).
CT4000-I-AUS.book Seite 21 Dienstag, 6. März 2018 1:18 13 CT4000 5.7 Installing the toilet Venting the cartridge tank Service door SK4 and SK5 j 1. 2. ➤ In the niche floor, create an opening with a diameter of approx. 12 mm (fig. j). ➤ Run the vent hose into this opening for discharge to the outside. Service door SK5 (optional) k ➤ Press the spray paint out of the inner frame of the door (fig. k). ➤ Install the door.
CT4000-I-AUS.book Seite 22 Dienstag, 6. März 2018 1:18 13 Electrical connection CT4000 l 1. 2. ➤ Insert the hose of the vent into the integrated vent opening of the service door and the cassette tank (fig. l). 6 Electrical connection ! A WARNING! Have the electrical connection carried out by an electrician. I 22 NOTICE! • Do not connect the toilet to the voltage supply directly in parallel with other power-consuming devices.
CT4000-I-AUS.book Seite 23 Dienstag, 6. März 2018 1:18 13 CT4000 Electrical connection 6.1 Connecting external water pump A NOTICE! • The rated capacity of an external water pump should not exceed 60 W. • The 12 V connection cable must have a cross-section of at least 1.5 mm². • A 7.5 A automotive fuse is integrated in the toilet control. m – + 1 – + 5 2 – 4 + 3 1 – + 5 2 – 12 V + 4 ➤ Connect the toilet via the main terminal block of the vehicle to its own power supply (fig. m).
CT4000-I-AUS.book Seite 24 Dienstag, 6. März 2018 1:18 13 Electrical connection CT4000 Key for fig. m, page 23: No. Designation 1 Control and operating panel of the toilet 2 Water pump (please note: not a pressurised water pump!) 3 switch 4 Fuse/main terminal box 5 12 Vg supply System schema of the control and operating panel plug assignment: n 2 + – bl – 1 + rt ws rt ws bl ws rt ➤ Connect the external water pump (fig. n). Key for fig. n: EN No.
CT4000-I-AUS.book Seite 25 Dienstag, 6. März 2018 1:18 13 CT4000 Electrical connection Wiring diagram for external water tank: o 1 bl sw 3 ws 2 4 gr gr br gr 5 bl X3 X4 X2 bl X1 7 br br 7.5 X0 6 rt ws input 12 V Key for fig. o: No.
CT4000-I-AUS.book Seite 26 Dienstag, 6. März 2018 1:18 13 Technical data 7 CT4000 Technical data CT4000 Supply voltage: Current consumption: Dimensions: 12 Vg Max. 2 A with internal pump Max. 5 A with external pump See fig. 4, page 9 to fig. 6, page 11 Operating temperature: 0 °C to +50 °C Required pump output: Min.
CT4000-I-AUS.book Seite 27 Dienstag, 6.
YOUR LOCAL SUPPORT YOUR LOCAL SALES OFFICE dometic.com/dealer dometic.com/contact dometic.com/sales-offices A complete list of Dometic companies, which comprise the Dometic Group, can be found in the public filings of: DOMETIC GROUP AB Hemvärnsgatan 15 SE-17154 Solna Sweden 4445101898 YOUR LOCAL DEALER 242 601744 12/2019 dometic.