Installation Guide
14
EN
Installing the toilet
4.7 Circuit diagram (external water tank)
Fig. 34
4.6.1.2 System diagrams (CTS 4110 models with external water pump)
Supply voltage: 12 V DC
12V connection cable profile : min. 1.5 mm²
Toilet control fuse : 7.5 A
(integrated automobile fuse)
Current consumption of the pump : max. 5A
The external water pump is not included in the
scope of delivery.
The external water pump must not exceed
a nominal power of 60 W (12V/5A).
NOTICE!
Fig. 33
12V DC
Control and operator panel
Pump
i
“More information https://www.caravansplus.com.au"