Installation Guide

12
EN
Installing the toilet
4.4 Water connection
The water supply is connected via an eletric
solenoid valve (1), which is fitted in the toilet
housing. Fit the fresh water supply pipe to the
water inlet (2) with a 1/2 NPT fitting.
Then check the leak tightness.
Fig. 27
1
2
The operating pressure range (water -
pressure) of the electric solenoid valve (1)
must not exceed 6 bar (87 PSI).
The electric solenoid valve will be dama-
ged by excessive pressure.
NOTICE!
4.5 Ventilation
Place the ventilation hose on the integrated
ventilation aperture of the service door as illu-
strated.
Fig. 29
Ventilation at SK5
Ventilation at SK4
Fig. 30
Fig. 28
Outside
Inside
a
a
Open the duct (a) for the ventilation hose in
the top area of the door frame (press out
spraying varnish on the outside, drill through
on the inside).
4.5.1 Ventilation with SK 5
Create an aperture in the floor (diameter
approx. 12 mm (0.47 )). Insert the ventilation
hose into this aperture.
4.5.2 Ventilation with SK 4
The SK4 service door is optionally available.
1
2
i
“More information https://www.caravansplus.com.au"