CRX Installing and connecting the refrigerator
21
Observe the following installation dimensions:
Keep objects clear of openings in the housing or installation structure (such as
ventilation slots, etc.).
Condensate is produced when the refrigerator is operating normally. You can
either wipe up the condensate on the floor of the refrigerator in regular intervals,
or drain it through a water drain outlet in the floor of the refrigerator (see chapter
“Mounting the water drain outlet (optional)” on page 21).
7.3 Mounting the water drain outlet (optional)
Connect a hose with an inside diameter of 10 mm (0.4 inch) (not included) to the
water drain outlet.
Lay the refrigerator on its side in order to access the bottom side.
Mount the water drain outlet (fig. 9 2, page 7) aligned to the front or to the
back according to the desired direction.
Remove the water drain plug (fig. 9 1, page 7) inside the refrigerator.
7.4 Installing the refrigerator
Proceed as follows to install the refrigerator:
If you wish to drain the condensate through a hose:
Mount the water drain port (see chapter “Mounting the water drain outlet
(optional)” on page 21)
Undo the transport lock (chapter “Releasing the lock” on page 27).
Open the refrigerator door.
Remove the blanking plugs (fig. 0 2, page 7).
Push the refrigerator into the recess.
Model Dimensions W x H x D (mm) Dimensions W x H x D (inch)
CRX50 390 x 544 x 550 15.35 x 21.42 x 21.65
CRX65 458 x 535 x 595 18.03 x 21.06 x 23.43
CRX80 485 x 650 x 578 19.09 x 25.59 x 22.76
CRX110 530 x 755 x 608 20.87 x 29.72 x 23.94
CRX140 550 x 825 x 670 21.65 x 32.48 x 26.38
CRX50-65-80-110-140-IO-US.book Seite 21 Montag, 22. Oktober 2018 11:01 11