Installation Manual

EN
Installing and connecting the refrigerator CRX
28
CRX50DC, CRX65DC, CRX80DC, CRX110DC
You can connect the refrigerator to 100 – 240 Vw AC power if you use the MPS35
rectifier (accessory).
The MPS35 rectifier features a priority circuit which conserves the battery con-
nected. When a 100 240 Vw mains connection is used, the rectifier automatically
switches from battery to mains operation.
When disconnected from the 100 240 Vw mains supply, the rectifier automatically
switches back to battery operation. Mains operation via the rectifier always takes pri-
ority over battery operation.
In mains operation the output voltage of the rectifier will always be 24 V. When the
rectifier is in 12 V or 24 V battery operation, the input voltage will be passed through
so that the output voltage equals the input voltage.
Proceed as follows when you connect the refrigerator to the AC supply:
Attach the rectifier on the back of the refrigerator.
Connect the rectifier as shown in fig. h.
Connect the refrigerator to the rectifier (fig. h 1):
Red cable (rd): positive battery terminal
Black cable (bk): negative battery terminal
Plug the connector (fig. h 2) into the AC socket.
12 V/24 V
10 A
+
+
1
2
rd/bk
rd
bk
bk
100 – 240 V~
h
DometicCRX50-65-80-110-140_IOM_4445103148_APAC(en)_20xx-xx-xx.book Seite 28 Montag, 3. August 2020 11:00 11