Product Manual

EN
Mounting the extractor hood CK150
12
I
Attach the fan (fig. 5 3, page 4) with the six included bolts (4.2 x 25).
Attach the roof hood (fig. 5 2, page 4) with the three included bolts (3.5 x 9.5).
Attach the cover cap (fig. 5 1, page 4) with the three included bolts (4.2 x 13).
6.2 Mounting the extractor hood
!
Choose a suitable installation location in the interior for the extractor hood.
Draw the location and size of the section of 381 x 142 mm on the bottom of the
suspended cabinet (fig. 4, page 4).
Pre-drill and cut out the section carefully with a keyhole saw or similar tool.
Insert the extractor hood from below into the cabinet and secure it with the four
included bolts (3.5 x 13) (fig. 6, page 5).
Attach the hose (fig. 6 3, page 4) to the extractor hood (fig. 6 5, page 4) and
the fan (fig. 6 1, page 4) with the hose clips (fig. 6 2 and 4, page 4).
Insert the filter (fig. 2 1, page 3) into the extractor hood.
6.3 Connecting the extractor hood electrically
Connect the fan to the battery; see fig. 7, page 6.
Key
NOTE
Pull the fan on tightly enough that the rubber seal is seamlessly in contact
with the roof.
WARNING!
Attach the extractor hood preferably over the cooking zone and
install it in a a suspended cabinet.
The distance between the gas hob flame and the extractor hood
must be at least 50 cm.
No. in
fig. 7,
page 6
Description
1Fan
2 Fuse holder with fuse T4 A 5 x 20 mm
CK150-IO-16s.book Seite 12 Mittwoch, 7. Dezember 2016 6:21 18