Operating Instructions and Installation Instructions

EN
Dometic CK150 Mounting the extractor hood
19
5.1 Control elements
6 Mounting the extractor hood
Note on installation location
The extractor hood should preferably be mounted above the cooking zone
and built into a suspended cabinet if possible. The distance between the gas
hob flame and the extractor hood must be at least 50 cm.
The fan should be mounted on the roof on a level surface. When mounted on
a sloping surface, the roof hood must be rotated so that one of the three wa-
ter drainage holes is directed toward the incline. A tilt angle up to 20° will not
affect the performance of the fan when the motor is not running.
6.1 Mounting the fan
Select an appropriate installation location for the fan on the roof.
Draw the location and size of the opening of 105 mm diameter (fig. 3,
page 3).
Pre-drill and cut out the hole on the roof carefully with a keyhole saw or
similar tool.
Place the fan on the opening and mark the six screw holes.
Apply a thin ring of a permanently elastic sealing material around each
hole.
Put the rubber seal (fig. 5 4, page 4) into the groove on the underside of
the fan.
No. in
fig. 2,
page 3
Description
1 Filter
2 Fan On/Off switch
3 Light On/Off switch
4 Halogen lamp