User Manual

EN
Operation CFX28 – CFX100W
18
In “HIGH” mode, the battery monitor responds faster than at the levels “LOW” and
“MED” (see the following table).
The battery monitor mode can be selected as follows:
➤ Switch on the cooler.
➤ Press the “SET” button (fig. 3 4, page 4) three times.
➤ Use the “UP +” (fig. 3 7, page 4) or “DOWN –” (fig. 3 6, page 4) buttons to
select the battery monitor mode.
✓ Display will be as follows:
Lo (LOW), Πd (MED), Hi (HIGH)
✓ The selected mode then appears in the display for a few seconds. The display
flashes several times before it returns to the current temperature.
I
Battery monitor mode LOW MED HIGH
Switch-off voltage at 12 V
10.1 V 11.4 V 11.8 V
Restart-voltage at 12 V
11.1 V 12.2 V 12.6 V
Switch-off voltage at 24 V
21.5 V 24.1 V 24.6 V
Restart voltage at 24 V
23.0 V 25.3 V 26.2 V
NOTE
When the cooler is supplied by the starter battery, select the battery
monitor mode “HIGH”. If the cooler is connected to a supply battery,
the battery monitor mode “LOW” will suffice.
CFX-28-CFX-100--B-EN-US.book Seite 18 Donnerstag, 9. März 2017 5:32 17