Specifications

11
FIG. 19
Upside
Down
Foam
Divider
Base Pan
Ceiling
Place Foam Divider in
(14-1/4" x 14-1/4" (±1/8")
Ceiling Opening against
Base Pan Bottom
Do Not Peel Tape Off
Adhesive
Foam Divider Ceiling
Level
(±1/4") Tear Off
Excess
FIG. 20
Foam Divider
Adhesive
Peel Off Paper - Center Divider - Stick To
Rear Flange On Ceiling Template
If bolts are left loose there may not be ad-
equate roof seal or if over tightened, damage
may occur to the air conditioner base or ceil-
ing template. Tighten to specifications listed
in this manual.
CAUTION
M
ic
r
o
-T
h
e
r
m
F
i
l
te
r
S
y
s
t
e
m
Micro-Therm
Filter
System
F
I
L
T
E
R
R
E
S
E
T
FILTER
RESET
C
LE
A
N
F
IL
T
E
R
CLEAN
FILTER
Return Air
Cover
FIG. 18
Grill
Foam
Divider
Ceiling
Template
Slider
Filter
Handle
Genesis Air Filtration System
Return Air Kit
620412, 620415, 620425 & 620426 Series Installation Instructions
Installing unit with 3308120 Genesis Air Filtration
System Return Air Kit. For unit with 3105007 or
3105935 Return Air Kit, see page 9.
1. All Non-Center Duct Installations
Note: The Genesis Air Filtration System can be installed on
units that use a center discharge duct through the 14-1/4" x
14-1/4" (±1/8") opening. Installing units with the center dis-
charge duct go to Section 1. "Center Discharge Duct Appli-
cation Installation", on page 12.
a. Check gasket alignment of the air conditioner
over the roof opening and adjust if necessary.
Unit may be moved from below by slightly lift-
ing and moving. See FIG. 12.
Remove return air cover, ceiling template,
foam divider and air filter from the 3308120
carton.
Locate the four (8" x 1/4-20) unit mounting
bolts, junction box cover and Romex con-
nector in the 3107180 bolt kit.
Pull down the units electrical cord and fas-
ten the junction box with screws to the fram-
ing in the front of the 14-1/4" x 14-1/4"(±1/
8") opening. See FIG. 13.
b. Measuring Foam Divider
Locate the foam divider and insert it cor-
ner to corner in the 14-1/4" x 14-1/4" (±1/
8") opening with the adhesive tape up (Do
not remove paper to expose adhesive). The
foam divider should be level with the ceiling
(±1/4"). Tear off the excess at the pre-cut
perforations in divider. See FIG. 19.
c. Install Foam Divider
Peel the paper off of the foam divider and
stick it in place on the center of the rear
flange of the return air opening on the ceil-
ing template. See FIG. 20.
d. Install Ceiling Template
Start each mounting bolt through the ceil-
ing template and up into the unit base pan
by hand. EVENLY tighten the four bolts
to a torque of 40 to 50 inch pounds. This
will compress the roof gasket to ap-
proximately 1/2". The bolts are self
locking so over tightening is not nec-
essary.