Specifications
6
11) Route a 4-conductor telephone cable from the
Comfort Control Center™ mounting position into
the 14" roof opening. Make sure that at least 15"
of the wire extends into the roof opening and 6"
extend from the wall at the mounting position of the
Comfort Control Center™.
12) In the event that other A/C's are to be installed
(additional zones) an additional 4-conductor tele-
phone cable must be routed to the other A/C's.
Make sure that at least 15" of the wire extends into
each of the roof openings. See FIG. 3.
C. AIR DISTRIBUTION DUCT
INSTALLATION
Install the Air Distribution Ducts in the RV Roof Cavity. The
Distribution System must meet:
1. RV’s requirements
2. System requirements listed in Section 3 of this
Manual.
Terminate the start of the Duct at the back edge of the
14" opening previously cut.
FIG. 3
FIG. 4