Specifications
2
MODEL NO.MODEL NO.
MODEL NO.MODEL NO.
MODEL NO.
.521 .621 .622 .521 .621 .622
.521 .621 .622 .521 .621 .622
.521 .621 .622
Nominal Capacity (BTU/HR) * 7,100 11,000 13,500 13,500 13,500 15,000 15,000 11,000 11,000 13,500 13,500 13,500
Electrical Rating 115 VAC, 60 Hz., 1 ph.
Compressor Rated Load Amps 6.6 8.5 11.5 12.1 11.0 12.9 12.9 9.5 10.7 12.4 11.5 11.5
Fan Motor Rated Load Amps 2.5 2.5 2.5 2.5 2.5 2.5 2.5 3.1 3.1 3.1 3.1 3.1
Compressor Locked Rotor Amps 34.0 48.3 50.0 59.0 54.4 71.0 71.0 53.0 50.0 60.0 50.0 50.0
Fan Motor Locked Rotor Amps 5.8 5.8 5.8 5.8 5.8 6.0 6.0 8.8 8.8 8.8 8.8 8.8
Heater Amps/Watts @ 120VAC NOT AVAILABLE ON THESE MODELS 2.7/1530 NOT AVAILABLE ON THESE MODELS
SCFM-High Speed Max./Min. 325 / 250 350/250 335/250
Total Static - Min/Max. 0.55 / 0.90" W.C. 0.40/1.10 0.12/0.65" W.C. .4/1.1
Refrigerant R22 Charge ( Oz.) 17.0 16.0 18.5 13.5 14.5 16.0 16.5 16.0 16.5 31.0 34.5 16.5 16.0 15.5 17.0 19.5
Minimum Wire Size
****
****
** 12 AWG Copper Up to 24 ft.
AC Circuit Protection 20 Amp Time Delay Fuse or 20 Amp HACR Circuit Breaker
DC Circuit Protection Installation must comply with all National, State, Providence, and/or local Electrical Codes
Installed Weight (Pounds) 75 94 100 94 94 102 105 95 101 96 102 102
Minimum Generator 1 Unit 2.5 KW 3.5 KW 2.5 KW 3.5 KW
Size
******
******
*** 2 Units 4.0 KW 5.0 KW 4.0 KW 5.0 KW
SPECIFICATIONS
5790857908
5790857908
57908
5951659516
5951659516
59516
.501.501
.501.501
.501
.506.506
.506.506
.506
.601.601
.601.601
.601
.606.606
.606.606
.606
600312600312
600312600312
600312
.321.321
.321.321
.321
59136.521
600312600312
600312600312
600312
.421.421
.421.421
.421
600315600315
600315600315
600315
.321.321
.321.321
.321
600315600315
600315600315
600315
.421.421
.421.421
.421
630035630035
630035630035
630035
.421.421
.421.421
.421
Maximum unit performance achieved at full rated voltage.
For distances over 24 ft. consult the National Electrical Code.
The Dometic Corporation gives GENERAL guidelines for generator
requirements. These guidelines come from experiences people have had
in actual applications. When sizing the generator, the total power usage of
your recreational vehicle must be considered. Also keep in mind genera-
tors lose power at high altitudes and from lack of maintenance.
***
**
*
A.This air conditioner is designed for:
1.Installation on a recreational vehicle at the time the
vehicle is manufactured.
2.Mounting on the roof of a recreational vehicle.
3.Connection to an air distribution system located in
the ceiling/roof cavity of the recreational vehicle.
4.Roof construction with rafters/joists on minimum of
16 inch centers.
5.Minimum of 2.00 inches and maximum of 5.50
inches distance between roof to ceiling of recre-
ational vehicle. Alternate installation methods will
allow for roofs more than 5.50 inches thick.
1.GENERAL INFORMATION
B. Condensation
NOTE
The manufacturer of this air conditioner will not be
responsible for damage caused by condensed mois-
ture on ceilings or other surfaces. Air contains mois-
ture and this moisture tends to condense on cold
surfaces. When air enters the RV, condensed mois-
ture may appear on the ceiling, windows, metal parts,
etc. The air conditioner removes this moisture from the
air during normal operation. Keeping doors and win-
dows closed when this air conditioner is in operation will
minimize condensed moisture on cold surfaces.
5791557915
5791557915
57915
.421 .421
.421 .421
.421
.426 .422 .426 .422
.426 .422 .426 .422
.426 .422
5791557915
5791557915
57915
.521 .522.521 .522
.521 .522.521 .522
.521 .522
.526.526
.526.526
.526
5791257912
5791257912
57912
5791557915
5791557915
57915
.621 .622.621 .622
.621 .622.621 .622
.621 .622
.626.626
.626.626
.626