Specifications

11
SUPPLY
1) Route the previously run power supply line through
the Romex Connector and into the Electronic
Control Kit Junction Box.
2) Connect the white to white; black to black; and
green to green or bare copper wire using appropri-
ate sized twist wire connectors. Tape the twist wire
connectors to the supply wiring to assure they do
not vibrate off.
3) Tighten screws on strain relief connector being
careful not to pinch and cut into the insulation on
power supply leads.
4) Push excess wires into junction box. Replace the
junction box cover onto the Electronic Control
Kit.
G. SYSTEM CHECKOUT &
CONFIGURATION
Now that the system is installed, it is necessary to check all
operations and then configure the electronics.
Refer to the Operating manual for a description of the air
conditioner operation.
1) SYSTEM CHECKOUT: Verify that all features of
the installed system work. Check fan speeds,
cooling mode, heat pump mode, furnace (if con-
nected) and heat strip. If the features do not work,
check all wiring and confirm that the correct op-
tions have been selected on the Electronic Control
Box. See Comfort Control Center™ Operating
Instructions.
2) SYSTEM CONFIGURATION: If all features are
functioning, perform the following configuration
procedure:
a. Simultaneously depress the UP and DN
pushbuttons on the Comfort Control Center
for one second. This completes the system
configuration.
H. INSTALLATION OF RETURN AIR COVER
1. Remove Return Air Grille from the Return Air Cover.
2. Place the Return Air Cover up to Ceiling Template.
3. Install Cover to Template with #8 x 3/8" blunt point
phillips head screws provided (6 required).
4. Reinstall Return Air Grille into Return Air Cover.
5. Install two (2) hole plugs into screw holes in back of
return air grille. Align tabs with mating notches and
snap filter into place. (See FIG. 18)
Return
Air Cov
e
Hole
Plugs
Return
Air
Grille
FIG. 18
ELECTRONIC FIELD WIRING DIAGRAM