Specifications
9
579 & 595 Installation Instructions
a. If another receiver mounting location is antici-
pated, observe the following general rules in
determining the location and submit location to
Dometic for approval.
• Locate the Receiver 54" above the floor.
• NEVER expose it to direct heat from lamps,
sun or other heat producing items.
• Avoid locations close to doors that lead
outside, windows or adjoining outside walls
or directly under cabinets or overhangs
which limit air movement.
• Avoid locations close to supply registers
and the air from them.
• NEVER locate receiver in a room that is
warmer or cooler than the rest of the RV.
• The major living area is normally a good
location.
2. Receiver Cable Installation
A 4-conductor receiver cable must be routed from the
roof opening to the Receiver
.
a. Choose the shortest, most direct route from the
14-1/4" x 14-1/4" (±1/8") opening to the Re-
ceiver
location selected. Leave 6" of cable
extending through the wall. See Section D-4.
b. The receiver cable that should be used is a flat,
4-conductor telephone cable.
c. The receiver cable must be terminated with two
(2) RJ-11-6C4P telephone connectors. Refer to
the crimp tool manufacture for crimping instruc-
tions.
Important: RJ-11-6C4P connectors must be installed
as shown in FIG. 10A, 10B and 10C.
Flat Four
Conductor Wire
Furnace
2 Wires
Furnace
AC Breaker
Box
AC Power
Supply Wires
DC Power
Supply 2 Wires
Air
Conditioner
Receiver
14-1/4" x 14-1/4"
(±1/8") Opening
FIG. 9
Flat Four Conductor Cable
RJ-11-6C4P
Connector
Pin 1
FIG. 10C
FIG. 10A
FIG. 10B
F. PLACING THE AIR CONDITIONER ON THE
ROOF
1. Remove the air conditioner from the carton . The unit
mounting bolts and literature are in a separate
plastic bag. Be sure to place this information in the
RV.
FIG. 11
Please Return to
Dometic All Return-
able Cartons Or
Recycle All Card-
board Cartons